0 |
10VT1000 |
1 |
Flow > 115% |
2 |
EEPROM |
3 |
Totalizer |
4 |
Qv > 115% QmaxDN (Error 9) |
5 |
Process variab. 2 |
6 |
Special Commands |
7 |
Primary |
8 |
Calculation |
9 |
Input/Output |
10 |
Display |
11 |
Unit |
12 |
Totalizer |
13 |
Pulse output |
14 |
Current output |
15 |
Diagnostic |
16 |
Adjust |
17 |
k-factor |
18 |
Flow Unit volume or mass |
19 |
Flow Unit |
20 |
Volume Flow Unit |
21 |
Volume Flow Unit |
22 |
Mass Flow Unit |
23 |
Mass Flow Unit |
24 |
Totalizer unit for volume and mass flow |
25 |
Totl.Unit |
26 |
Frequency Unit |
27 |
Frequency Unit |
28 |
Density Unit |
29 |
Density Unit |
30 |
Qv |
31 |
Qn |
32 |
Qm |
33 |
Operating Flow Qv. Flow under operating conditions = operating temperature and operating pressure. |
34 |
.2f |
35 |
|
36 |
Volume Flow Qv |
37 |
Standard Flow Qv |
38 |
Standard Flow Qv. Flow under standard conditions = standard temperature and standard pressure. |
39 |
Mass Flow Qm |
40 |
Mass Flow Qm. Flow under mass conditions = operating temperature and operating pressure. |
41 |
Totalizer. Integral of operating flow or mass flow - depends from flow mode. |
42 |
Frequency |
43 |
Frequency of whirl in primary. |
44 |
.1f |
45 |
Totl. |
46 |
Q |
47 |
Reset Conf.Changed |
48 |
Totalizer reset |
49 |
Reset Error register |
50 |
Primary |
51 |
Primary can be selected as a Vortex or swirl type |
52 |
Swirl |
53 |
Vortex |
54 |
Medium |
55 |
Medium can be gas or liquid |
56 |
Gas |
57 |
Liquid |
58 |
Metersize Swirl |
59 |
Selection of swirl type primary meter size |
60 |
15 mm 1/2 in |
61 |
20 mm 3/4 in |
62 |
25 mm 1 in |
63 |
32 mm 1-1/4 in |
64 |
40 mm 1-1/2 in |
65 |
50 mm 2 in |
66 |
80 mm 3 in |
67 |
100 mm 4 in |
68 |
150 mm 6 in |
69 |
200 mm 8 in |
70 |
300 mm 12 in |
71 |
400 mm 16 in |
72 |
Metersize Vortex |
73 |
Selection of Vortex type primary meter size |
74 |
DIN 15mm 0.5in |
75 |
DIN 25mm 1in |
76 |
DIN 40mm 1.5in |
77 |
DIN 50mm 2in |
78 |
DIN 80mm 3in |
79 |
DIN 100mm 4in |
80 |
DIN 150mm 6in |
81 |
DIN 200mm 8in |
82 |
DIN 250mm 10in |
83 |
DIN 300mm 12in |
84 |
ANSI 15mm 0.5in |
85 |
ANSI 25mm 1in |
86 |
ANSI 40mm 1.5in |
87 |
ANSI 50mm 2in |
88 |
ANSI 80mm 3in |
89 |
ANSI 100mm 4in |
90 |
ANSI 150mm 6in |
91 |
ANSI 200mm 8in |
92 |
ANSI 250mm 10in |
93 |
ANSI 300mm 12in |
94 |
QmaxDN mode |
95 |
Can define QmaxDN-Mode from fixed to variable mode. |
96 |
fixed |
97 |
programable |
98 |
Operation mode |
99 |
Different selections for operating mode of the instrument |
100 |
Operation |
101 |
Standard |
102 |
Mass |
103 |
Language |
104 |
Available languages on the instrument display for textes. |
105 |
German |
106 |
English |
107 |
Display 1. line |
108 |
Select the parameter to be shown on the fist line of the instrument display. |
109 |
Qv operation |
110 |
Qm mass |
111 |
Percent |
112 |
Percent panel |
113 |
Qn standard |
114 |
Display 2. line |
115 |
Select the parameter to be shown on the second line of the instrument display. |
116 |
Unit Qv |
117 |
Available units for operation flow value |
118 |
Unit Qm |
119 |
Available units for massflow value. |
120 |
Unit vol. tot. |
121 |
Available units for operation flow totalizer. |
122 |
Unit mass tot. |
123 |
Available units for massflow totalizer. |
124 |
Unit density |
125 |
Available units for density. |
126 |
Current at alarm |
127 |
Current output settings at alarm status. |
128 |
22.40 mA |
129 |
3.85 mA |
130 |
Modes for current output operation. Be careful, with setting to current+pulse you loose HART communication! |
131 |
Current + HART |
132 |
Current + pulse |
133 |
Error 9 |
134 |
Error 9 modes. Please refer to instruction book. |
135 |
off |
136 |
on |
137 |
k-linearisation |
138 |
Modes for k-factor linearisation. |
139 |
Mean value |
140 |
2 points |
141 |
3 points |
142 |
4 points |
143 |
5 points |
144 |
col uc_var |
145 |
help unsigned char variables |
146 |
Instrument no. |
147 |
Instrument number. |
148 |
5u |
149 |
Description geraetenummer |
150 |
Overflow |
151 |
Number of totalizer overflows. Please refer to instruction book for more information. |
152 |
Pulse width |
153 |
Parameter for pulse width for pulse output. Only in mode current+pulse. |
154 |
msek |
155 |
3u |
156 |
mains interrupt |
157 |
Number of power supply interruptions since starting up the instrument. |
158 |
Code number |
159 |
Enter the service code number for changing of protected parameters. |
160 |
f1 |
161 |
Frequency point f1 for k-factor linearisation. |
162 |
4u |
163 |
f2 |
164 |
Frequency point f2 for k-factor linearisation. |
165 |
f3 |
166 |
Frequency point f3 for k-factor linearisation. |
167 |
f4 |
168 |
Frequency point f4 for k-factor linearisation. |
169 |
f5 |
170 |
Frequency point f5 for k-factor linearisation. |
171 |
col ui_var |
172 |
help ui variables |
173 |
QmaxDN operation |
174 |
Maximum flow value of metersize at operation mode. |
175 |
8.2f |
176 |
Qmax |
177 |
Value for upper span. |
178 |
Qmin |
179 |
Value for lower span. |
180 |
norm. factor |
181 |
Factor for flow calculation due to standard conditions. |
182 |
8.3f |
183 |
Operation density |
184 |
Value for density at operation conditions for massflow calculation. |
185 |
Pulse factor |
186 |
Value of pulse factor for totalizer calculation. |
187 |
7.3f |
188 |
Damping |
189 |
Time constant for current output damping. |
190 |
5.1f |
191 |
mean k-factor |
192 |
Mean k-factor value of primary, Please refer to the calibration protocol. |
193 |
8.1f |
194 |
k1 |
195 |
K-factor k1 is related to frequency f1. Please refer to calibration protocol! |
196 |
k2 |
197 |
K-factor k2 is related to frequency f2. Please refer to calibration protocol! |
198 |
k3 |
199 |
K-factor k3 is related to frequency f3. Please refer to calibration protocol! |
200 |
k4 |
201 |
K-factor k4 is related to frequency f4. Please refer to calibration protocol! |
202 |
k5 |
203 |
K-factor k5 is related to frequency f5. Please refer to calibration protocol! |
204 |
col fl_var |
205 |
help fl variables |
206 |
FMU860 |
207 |
DT |
208 |
DVC |
209 |
FCX |
210 |
AS800 |
211 |
340T |
212 |
340C |
213 |
344 |
214 |
Siemens Micro K |
215 |
SITRANS L |
216 |
SIPAN PH |
217 |
SITRANS P |
218 |
75SMT |
219 |
UNIDELTA |
220 |
8320 |
221 |
SX5100 |
222 |
TSV175 |
223 |
DMU |
224 |
3780 |
225 |
BM70 |
226 |
8u |
227 |
4.2f |
228 |
6.2f |
229 |
7d |
230 |
Sensor |
231 |
Sensor Info |
232 |
Input |
233 |
Outputs |
234 |
Analog Output |
235 |
HART Output |
236 |
Reset Configuration Changed Flag ? |
237 |
Reset totalizer? |
238 |
Reset Error register? |