0 |
50XM1000 |
1 |
50SM1000 |
2 |
10VT1000 |
3 |
50VM1000 |
4 |
10A5400 |
5 |
Process Variab. 2 |
6 |
Special Commands |
7 |
Primary |
8 |
Calculation |
9 |
Input/Output |
10 |
Display |
11 |
Unit |
12 |
Totalizer |
13 |
Pulse output |
14 |
Current output |
15 |
Alarm |
16 |
Pressure input |
17 |
PT-Modul |
18 |
Data link |
19 |
Diagnostics |
20 |
Error register |
21 |
Adjust |
22 |
Adjust Iin/Iout |
23 |
Freq. measurement |
24 |
k-factor |
25 |
Master Reset |
26 |
Totalizer reset |
27 |
Error Reset |
28 |
Flow Unit |
29 |
Flow Unit Help |
30 |
Volume Flow Unit |
31 |
Volume Flow Unit Help |
32 |
Mass Flow Unit |
33 |
Mass Flow Unit Help |
34 |
Totalizer Unit |
35 |
Totalizer Unit Help |
36 |
Frequency Unit Help |
37 |
Frequency Unit |
38 |
Density Unit |
39 |
Density Unit Help |
40 |
Pressure Unit |
41 |
Pressure Unit Help |
42 |
Temperature unit |
43 |
Temperature Unit Help |
44 |
Error register MSB |
45 |
Error register MSB. Please refer to instruction manual! |
46 |
Temperature |
47 |
Qv > 115% QmaxDN |
48 |
Error register LSB |
49 |
Error register LSB. Please refer to instruction manual! |
50 |
Steam calculation |
51 |
Preamplifier |
52 |
Flowrate >115% |
53 |
Ext. shut down |
54 |
EEPROM |
55 |
Totalizer checksum error |
56 |
Pressure |
57 |
Log. register MSB |
58 |
Logging register MSB. Please refer to instruction manual! |
59 |
Log. register LSB |
60 |
Logging register LSB. Please refer to instruction manual! |
61 |
Status register |
62 |
Status register. Please refer to instruction manual! |
63 |
Ext.total. reset |
64 |
Maximum Alarm |
65 |
Minimum Alarm |
66 |
Low flow cut-off |
67 |
Test mode opera. |
68 |
Remote Mode |
69 |
Test-function reg. |
70 |
Register of test function results. Please refer to instruction manual! |
71 |
Test running |
72 |
Test finished |
73 |
RAM |
74 |
NVRAM |
75 |
EPROM |
76 |
Int. EEPROM |
77 |
Ext. EEPROM |
78 |
Q |
79 |
Actual Flow Qv. Flow under actual conditions = actual temperature and pressure. |
80 |
.2f |
81 |
Standard Flow Qn |
82 |
Standard Flow Qn. Flow under standard conditions = standard temperature and pressure. |
83 |
Mass Flow Qm |
84 |
Mass Flow Qm. Operating flow multiplied with operating density. |
85 |
Volume Flow Qv |
86 |
Operating Flow Qv. Flow under operating conditions = operating temperature and operating pressure. |
87 |
Totl. |
88 |
Totalizer. Integral of operating flow or mass flow - depends from flow mode. |
89 |
P |
90 |
Pressure value for PT calculation. |
91 |
.1f |
92 |
T |
93 |
Temperature Value for PT-calculation. |
94 |
F |
95 |
Frequency value. |
96 |
Qn |
97 |
Qm |
98 |
Qv |
99 |
Language |
100 |
List of selectable languages for display information. |
101 |
German |
102 |
English |
103 |
Select primary type in between Vortex and Swirl. |
104 |
Swirl |
105 |
Vortex |
106 |
Medium |
107 |
Select medium out of list. |
108 |
Gas |
109 |
Liquid |
110 |
Hot steam |
111 |
Saturated steam |
112 |
Metersize Swirl |
113 |
Selectable metersizes of Swirl primary. |
114 |
PIE 15 mm 0.5 in |
115 |
PIE 20 mm 0.75 in |
116 |
PIE 25 mm 1 in |
117 |
PIE 32 mm 1.25 in |
118 |
PIE 40 mm 1.5 in |
119 |
PIE 50 mm 2 in |
120 |
PIE 80 mm 3 in |
121 |
PIE 100 mm 4 in |
122 |
PIE 150 mm 6 in |
123 |
PIE 200 mm 8 in |
124 |
PIE 300 mm 12 in |
125 |
PIE 400 mm 16 in |
126 |
NTC 15 mm 0.5 in |
127 |
NTC 20 mm 0.75 in |
128 |
NTC 25 mm 1 in |
129 |
NTC 32 mm 1.25 in |
130 |
NTC 40 mm 1.5 in |
131 |
NTC 50 mm 2 in |
132 |
NTC 80 mm 3 in |
133 |
NTC 100 mm 4 in |
134 |
NTC 150 mm 6 in |
135 |
NTC 200 mm 8 in |
136 |
NTC 300 mm 12 in |
137 |
NTC 400 mm 16 in |
138 |
Metersize Vortex |
139 |
Seletable metersizes of Vortex primary. |
140 |
DIN 15mm 0.5 in |
141 |
DIN 25mm 1 in |
142 |
DIN 40mm 1.5 in |
143 |
DIN 50mm 2 in |
144 |
DIN 80mm 3 in |
145 |
DIN 100mm 4 in |
146 |
DIN 150mm 6 in |
147 |
DIN 200mm 8 in |
148 |
DIN 250mm 10 in |
149 |
DIN 300mm 12 in |
150 |
ANSI 15mm 0.5 in |
151 |
ANSI 25mm 1 in |
152 |
ANSI 40mm 1.5 in |
153 |
ANSI 50mm 2 in |
154 |
ANSI 80mm 3 in |
155 |
ANSI 100mm 4 in |
156 |
ANSI 150mm 6 in |
157 |
ANSI 200mm 8 in |
158 |
ANSI 250mm 10 in |
159 |
ANSI 300mm 12 in |
160 |
Operation mode |
161 |
Select operation mode out of list. |
162 |
Actual |
163 |
Standard |
164 |
Mass |
165 |
Gas calculation |
166 |
Various gas calculations. |
167 |
Ideal Gas |
168 |
Correction factor |
169 |
Van der Waals |
170 |
VdW gas table |
171 |
VdW gas table constants. |
172 |
Oxygen |
173 |
Nitrogen |
174 |
Helium |
175 |
Hydrogen |
176 |
Argon |
177 |
Neon |
178 |
Chlorine |
179 |
Carbon monoxide |
180 |
Carbon dioxide |
181 |
Sulfur dioxide |
182 |
Nitric oxide |
183 |
Ammonia |
184 |
Hydrogen chloride |
185 |
Hydrogen sulfide |
186 |
Methane |
187 |
Acetylene |
188 |
Ethylene |
189 |
Ethane |
190 |
Propylene |
191 |
Propane |
192 |
Benzene |
193 |
n-Butane |
194 |
--- |
195 |
Standard condition |
196 |
Standard conditions for medium pressure and temperature at calculation. |
197 |
1.0133bara 0C |
198 |
1.0133bara 20C |
199 |
Saturated steam calculation. |
200 |
Temp. measurement |
201 |
Pressure measurement |
202 |
Display line 1 |
203 |
Parameter to be shown on the first display line. |
204 |
Qv actual |
205 |
Qn standard |
206 |
Qm Mass |
207 |
Percent |
208 |
Percent bargraph |
209 |
Pessure + Temp. |
210 |
Frequency |
211 |
Display line 2 |
212 |
Parameter to be shown on the second display line. |
213 |
Multiplex line 2 |
214 |
Two parameters to be multiplexed shown on the second display line. |
215 |
Multiplex |
216 |
Multiplex mode of display lines. |
217 |
off |
218 |
on |
219 |
Table for current output settings. For HART operation allways 4-20mA! |
220 |
0-20mA |
221 |
4-20mA |
222 |
0-10mA |
223 |
2-10mA |
224 |
0-5mA |
225 |
Current at Alarm |
226 |
Current output value at alarm status. |
227 |
130% |
228 |
0% |
229 |
Pressure input definitions. Please refer to instruction manual! |
230 |
Set temperature measurement to on or off. |
231 |
Press. measurement |
232 |
Set pressure measurement to on or off |
233 |
Communication |
234 |
Select communication mode. On any other mode than HART, you will loose HART function! |
235 |
HART |
236 |
ASCII |
237 |
Printer 7 |
238 |
Printer 8 |
239 |
Printer 9 |
240 |
Baudrate |
241 |
Baudrate selection. For HART allways 1200Baud! |
242 |
110 |
243 |
300 |
244 |
600 |
245 |
1200 |
246 |
2400 |
247 |
4800 |
248 |
9600 |
249 |
14400 |
250 |
19200 |
251 |
28800 |
252 |
Printer type |
253 |
Select a printer type. Not useful for HART comunication! |
254 |
F&P Docuprint |
255 |
Standard Cr Lf |
256 |
Error 9 |
257 |
Error 9 definition. Please refer to the instruction manual! |
258 |
k-linearisation |
259 |
Kind and number of points for k-factor linearisation |
260 |
Mean value |
261 |
2 points |
262 |
3 points |
263 |
4 points |
264 |
5 points |
265 |
Unit Qv |
266 |
Seletable units for actual flow Qv. |
267 |
l/s |
268 |
l/m |
269 |
l/h |
270 |
m3/s |
271 |
m3/m |
272 |
m3/h |
273 |
m3/d |
274 |
ft3/s |
275 |
ft3/m |
276 |
ft3/h |
277 |
ft3/d |
278 |
usgps |
279 |
usgpm |
280 |
usgph |
281 |
usmgd |
282 |
igl/s |
283 |
igl/m |
284 |
igl/h |
285 |
igl/d |
286 |
bbl/s |
287 |
bbl/m |
288 |
bbl/h |
289 |
bbl/d |
290 |
Unit Qm |
291 |
Selectable units for massflow Qm. |
292 |
g/s |
293 |
g/m |
294 |
g/h |
295 |
kg/s |
296 |
kg/m |
297 |
kg/h |
298 |
kg/d |
299 |
t/m |
300 |
t/h |
301 |
t/d |
302 |
lb/s |
303 |
lb/m |
304 |
lb/h |
305 |
lb/d |
306 |
Unit Zv |
307 |
Selectable units for actual flow totalizer Zv. |
308 |
l |
309 |
m3 |
310 |
ft3 |
311 |
usgal |
312 |
igal |
313 |
bbl |
314 |
Unit Zm |
315 |
Selectable units for massflow totalizer Zm. |
316 |
g |
317 |
kg |
318 |
t |
319 |
lb |
320 |
Unit density |
321 |
Selectable units for density value. |
322 |
g/ml |
323 |
g/cm3 |
324 |
g/l |
325 |
kg/l |
326 |
kg/m3 |
327 |
lb/ft3 |
328 |
lb/ugl |
329 |
Unit k-factor |
330 |
Selectable units for k-factor values. |
331 |
1/m3 |
332 |
1/ft3 |
333 |
Unit temp. |
334 |
Selectable units for temperature value. |
335 |
C |
336 |
F |
337 |
Unit pressure |
338 |
Selectable units for pressure value. |
339 |
bar |
340 |
PSIA |
341 |
col uc_var |
342 |
help unsigned char variables |
343 |
Overflow |
344 |
Totalizer overflow counter. Please refer to the instruction manual! |
345 |
5u |
346 |
Min. frequency |
347 |
Minimum frequency value to interpreated as a flow signal. |
348 |
4u |
349 |
Max. frequency |
350 |
Maximum frequency value to be interpreated as a flow signal. |
351 |
Instrument address |
352 |
Instrument address for communication. |
353 |
2u |
354 |
Mains interrupts |
355 |
Number of power supply interuptions since startup. |
356 |
F&P service no. |
357 |
Code number to get access to factory settings. |
358 |
Instrument no. |
359 |
Production number of this instrument. |
360 |
Description geraetenummer |
361 |
f1 |
362 |
Frequency f1 for k-factor linearisation. Please refer to calibration protocol! |
363 |
f2 |
364 |
Frequency f2 for k-factor linearisation. Please refer to calibration protocol! |
365 |
f3 |
366 |
Frequency f3 for k-factor linearisation. Please refer to calibration protocol! |
367 |
f4 |
368 |
Frequency f4 for k-factor linearisation. Please refer to calibration protocol! |
369 |
f5 |
370 |
Frequency f5 for k-factor linearisation. Please refer to calibration protocol! |
371 |
col ui_var |
372 |
help ui variables |
373 |
Correction factor for gases. Please refer to instruction manual. |
374 |
5.3f |
375 |
|
376 |
Van der Waals a |
377 |
Van der Vaals calculation factor a. Please refer to instruction manual. |
378 |
8.5f |
379 |
Van der Waals b |
380 |
Van der Vaals calculation factor b. Please refer to intruction manual. |
381 |
7.5f |
382 |
Vol. extension |
383 |
Volume extension of liquids as a function of temperature. |
384 |
%./C |
385 |
5.2f |
386 |
Standard density |
387 |
Density of medium at standard conditions for pressure and temperature. |
388 |
8.3f |
389 |
QmaxDN Operation |
390 |
QmaxDN. Maximum actual flow of metersize. |
391 |
8.2f |
392 |
Qmax |
393 |
Maximum possible flow under operating conditions for pressure and temperature. |
394 |
Qmin |
395 |
Minimum flow at operating conditions for pressure and temperature. |
396 |
Pulse factor |
397 |
Pulse factor definition. |
398 |
7.3f |
399 |
Pulsewidth |
400 |
Value for pulsewidth of pulse output. |
401 |
msek |
402 |
Damping |
403 |
Damping of current output process value. |
404 |
5.1f |
405 |
Max-Alarm > |
406 |
Setpoint for max. alarm generation. |
407 |
Min-Alarm < |
408 |
Setpoint for min. alarm generation. |
409 |
Pressure 0% |
410 |
Pressure value for 0% |
411 |
6.2f |
412 |
Pressure 100% |
413 |
Pressure value for 100% |
414 |
const. Temp. |
415 |
Constant value for temperature. Used if temperatue measurement is not available or in off mode. |
416 |
6.1f |
417 |
const. Pressure |
418 |
Constant value for pressure. Used if pressure measurement is not available or in off mode. |
419 |
Frequ. hold time |
420 |
Time to hold last measured value if there are bad quality signals with drop outs. |
421 |
4.1f |
422 |
Adjust Iout 4 mA |
423 |
Adjust 4 mA current output value. |
424 |
6.3f |
425 |
Adjust Iout 20 mA |
426 |
Adjust 20 mA current output value. |
427 |
Adjust Iin 4 mA |
428 |
Adjust 4 mA current input value for pressure transmitter. |
429 |
Adjust Iin 20 mA |
430 |
Adjust 20 mA current input value for pressure transmitter. |
431 |
Mean k-factor |
432 |
K-factor linearisation in off mode. Use the mean k-factor of calibration. |
433 |
8.1f |
434 |
k1 |
435 |
k-factor k1 for k-factor linearisation. Please refer to calibration protocol! |
436 |
k2 |
437 |
k-factor k2 for k-factor linearisation. Please refer to calibration protocol! |
438 |
k3 |
439 |
k-factor k3 for k-factor linearisation. Please refer to calibration protocol! |
440 |
k4 |
441 |
k-factor k4 for k-factor linearisation. Please refer to calibration protocol! |
442 |
k5 |
443 |
k-factor k5 for k-factor linearisation. Please refer to calibration protocol! |
444 |
col fl_var |
445 |
help fl variables |
446 |
FMU860 |
447 |
DT |
448 |
DVC |
449 |
FCX |
450 |
AS800 |
451 |
340T |
452 |
340C |
453 |
344 |
454 |
Siemens Micro K |
455 |
SITRANS L |
456 |
SIPAN PH |
457 |
SITRANS P |
458 |
75SMT |
459 |
UNIDELTA |
460 |
8320 |
461 |
SX5100 |
462 |
TSV175 |
463 |
DMU |
464 |
3780 |
465 |
BM70 |
466 |
8u |
467 |
4.2f |
468 |
7d |
469 |
About to perform xmtr self test |
470 |
Performing self test |
471 |
Aborting method. Device maybe stuck in selftest. |
472 |
Self test passed |
473 |
Sensor |
474 |
Input |
475 |
Outputs |
476 |
Analog Output |
477 |
HART Output |
478 |
About to perform Master Reset |
479 |
reset counter? |
480 |
reset error register |
481 |
Performing self test RAM, NVRAM, EPROM, EEPROM (int + ext) PLEASE WAIT |
482 |
Self test passed, no error |