Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
pressure_units | 138D | Unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 8 |
pressure_value | 138E | Pres | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pressure_percent_range | 138F | % rnge | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 34 |
pressure_upper_range_limit | 1393 | USL | Upper Sensor Limit Value- Defines the maximum useable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_lower_range_limit | 1394 | LSL | Lower Sensor Limit Value- Defines the minimum useable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_minimum_span | 1390 | Min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
pressure_output_transfer_function | 1391 | Transfer function | Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 32 |
pressure_upper_range_value | 1396 | URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Float | 32 |
pressure_lower_range_value | 1397 | LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Float | 32 |
pressure_damping_value | 1398 | Damping | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Float | 8 |
flange_type | 139A | Process conn type | Process Connector Type - Hardware adjacent to the sensor, that physically connects the process to the sensor.Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 2048 |
remote_seal_type | 139D | RS type | Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. | R/W | Enum | 2048 |
module_fill_fluid | 139E | Fill fluid | Sensor Fill Fluid- Fluid material in the module. | R/W | Enum | 2048 |
number_of_remote_seals | 139F | Num remote seal | Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed. | R/W | Enum | 2048 |
temperature_value | 4001 | Snsr temp | Field Device Variable Value- Digital value that changes with respect to process or ambient temperature over time with no user intervention. Sensor Temperature- Temperature associated with the sensor that is responsible for a process measurement. | R | Float | 10 |
temperature_units | 4024 | Snsr temp unit | Field Device Variable Unit- Digital unit that the variable will be displayed with. Sensor Temperature- Temperature associated with the sensor that is responsible for a process measurement. | R/W | Enum | 8 |
static_pressure_value | 4002 | Static Pres | R | Float | 10 | |
static_pressure_units | 4025 | Static Pres unit | R/W | Enum | 8 | |
low_cut_point | 400A | Low cut | R/W | Float | 2048 | |
low_cut_mode | 400B | Cut mode | R/W | Enum | 2048 | |
bi_dir_mode | 400F | Bi-dir mode | R/W | Enum | 2048 | |
disp_mode | 4016 | Display mode | R/W | Enum | 2048 | |
disp_func | 4017 | Display fnctn | R/W | Enum | 2048 | |
engr_disp_unit | 4003 | Engr unit | R/W | PackedAscii | 2048 | |
engr_disp_lrv | 4018 | Engr disp LRV | R/W | Float | 2048 | |
engr_disp_urv | 4019 | Engr disp URV | R/W | Float | 2048 | |
engr_disp_point | 401A | Engr disp point | R/W | Enum | 2048 | |
engr_disp_value | 4004 | Engr disp | R | Float | 2050 | |
module_range_code | 4000 | Module rnge | Module range number- pressure range number located on the side of the sensor | R | Enum | 2048 |
gasket_material | 4012 | Gasket matl | Gasket Material- Construction material of a seal that exists between the module and flange. | R/W | Enum | 2048 |
remote_seal_fill_fluid | 4014 | RS fill fluid | Remote Seal Fill Fluid- Fluid material in the device remote seal. | R/W | Enum | 2048 |
flange_size | 4013 | Process conn size | Process Connector Size - Hardware adjacent to the sensor, that physically connects the process to the sensor. | R/W | Enum | 2048 |
ext_sw_mode | 4015 | Ext SW mode | R/W | Enum | 2048 | |
asc_model | 4026 | Model | R/W | PackedAscii | 2048 | |
asc_serial_no | 401B | Serial No. | R | PackedAscii | 2048 | |
h2o_unit_select | 4010 | H2O Unit select | R/W | Enum | 2048 | |
si_option | 4049 | SI Option | R/W | Enum | 2048 | |
joker_passwd_log | 404D | Software seal | R | Enum | 2048 | |
enable_write_password | 4052 | Enable wrt passwd | R/W | PackedAscii | 2048 | |
new_password | 4053 | New password | R/W | PackedAscii | 2048 | |
unique_device_type_code | 07ED | R/W | Enum | 4096 | ||
rosemount_model_code | 07F5 | R/W | Enum | 4096 | ||
rosemount_analytical_model_code | 07F6 | R/W | Enum | 4096 | ||
kayray_model_code | 07F7 | R/W | Enum | 4096 | ||
micro_motion_model_code | 07F8 | R/W | Enum | 4096 | ||
units_code | 07E9 | R/W | Enum | 4096 | ||
transfer_function_code | 07EA | R/W | Enum | 4096 | ||
material_code | 07EC | R/W | Enum | 4096 | ||
alarm_selection_code | 07EB | R/W | Enum | 4096 | ||
write_protect_code | 07EE | R/W | Enum | 4096 | ||
Name | ID | Label | Description | Type | Access | Class |