Name ID Label Description Type Access Class
pressure_units 138D Unidades Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Enum 8
pressure_value 138E Pressão Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 10
pressure_percent_range 138F % de faixa Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 34
pressure_upper_range_limit 1393 USL Upper Sensor Limit Value- Defines the maximum useable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 8
pressure_lower_range_limit 1394 LSL Lower Sensor Limit Value- Defines the minimum useable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 8
pressure_minimum_span 1390 Intervalo mínimo Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 8
pressure_output_transfer_function 1391 Função de tranferência Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Enum 32
pressure_upper_range_value 1396 URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Float 32
pressure_lower_range_value 1397 LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Float 32
pressure_damping_value 1398 Amortecimento Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Float 8
flange_type 139A Process conn type Process Connector Type - Hardware adjacent to the sensor, that physically connects the process to the sensor.Pressure- Pressure of the process measured with respect to a reference pressure. R/W Enum 2048
remote_seal_type 139D Tipo de selo remoto Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. R/W Enum 2048
module_fill_fluid 139E Preencher fluído Sensor Fill Fluid- Fluid material in the module. R/W Enum 2048
number_of_remote_seals 139F Número do selo remoto Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed. R/W Enum 2048
temperature_value 4001 Temperatura de sensor Field Device Variable Value- Digital value that changes with respect to process or ambient temperature over time with no user intervention. Sensor Temperature- Temperature associated with the sensor that is responsible for a process measurement. R Float 10
temperature_units 4024 Snsr temp unit Field Device Variable Unit- Digital unit that the variable will be displayed with. Sensor Temperature- Temperature associated with the sensor that is responsible for a process measurement. R/W Enum 8
static_pressure_value 4002 Static Pres R Float 10
static_pressure_units 4025 Static Pres unit R/W Enum 8
low_cut_point 400A Low cut R/W Float 2048
low_cut_mode 400B Cut mode R/W Enum 2048
bi_dir_mode 400F Bi-dir mode R/W Enum 2048
disp_mode 4016 Display mode R/W Enum 2048
disp_func 4017 Display fnctn R/W Enum 2048
engr_disp_unit 4003 Engr unit R/W PackedAscii 2048
engr_disp_lrv 4018 Engr disp LRV R/W Float 2048
Name ID Label Description Type Access Class