Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
pv_sensor_limit_units | 4008 | Pressure unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure | R/W | Enum | 10 |
pv_upper_sensor_limit | 4009 | Pres USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pv_lower_sensor_limit | 400A | Pres LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pv_value | 4001 | R | Float | 10 | ||
pv_value_units | 4000 | PV unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 10 |
pv_damping_value | 400B | PV Damp | R/W | Float | 10 | |
pv_minimum_span | 400C | Pres min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
pv_serial_number | 400D | Pres snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 2048 |
pv_channel | 400E | Input channel | R | Unsigned | 8 | |
percentageValue | 4003 | SV (Percent) | R | Float | 10 | |
percentageUnits | 4002 | % | R | Enum | 10 | |
outputCurrentValue | 4005 | TV (Loop current) | R | Float | 10 | |
outputCurrentUnits | 4004 | Flow Unit | R/W | Enum | 10 | |
temperatureValue | 4007 | QV (Temperature) | Sensor Temperature- Temperature of the sensor that is making the process measurement | R | Float | 10 |
temperatureUnits | 4006 | Temperature Unit | Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. | R/W | Enum | 8 |
flowUnits | 4010 | Flow Unit | Sensor Flow Units- Engineering unit to be displayed with Sensor flow. | R/W | Enum | 8 |
zero_elevation | 4011 | ZERO ELEV. | Measure zero offset value | R/W | Float | 2048 |
regulated_current_zero | 4012 | Zero Current | W | Float | 2048 | |
regulated_current_gain | 4013 | Gain Current | W | Float | 2048 | |
spec_gravity | 4014 | HEAVIER SG | R/W | Float | 2048 | |
spec_gravity_light | 4015 | LIGHTER SG | R/W | Float | 2048 | |
ADC0_value | 4016 | ADC0 Value | R | Float | 2048 | |
ADC1_value | 4017 | ADC1 Value | R | Float | 2048 | |
URV_span_adjustment | 4018 | SPAN URV Value | Edit the full scale adjustment parameter | R/W | Float | 2048 |
device_status | 0097 | Device status | Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process | R | BitEnum | 131 |
manufacturer_id | 0099 | Manufacturer | Manufacturer Identification Code- References a specific manufacturer, which is usually a company name, that is responsible for the manufacture of this Field Device. | R | Enum | 128 |
device_type | 009A | Model | Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer | R | Enum | 128 |
physical_signaling_code | 00AB | Physicl signl code | Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port | R | Enum | 2048 |
device_flags | 00A0 | Dev flags | Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer | R | BitEnum | 2048 |
private_label_distributor | 00A8 | Distributor | Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers | R | Enum | 2048 |
units_code | 07E9 | R/W | Enum | 4096 | ||
write_protect | 00A7 | Write protect | Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. | R | Enum | 2050 |
transfer_function_code | 07EA | R/W | Enum | 4096 | ||
alarm_selection_code | 07EB | R/W | Enum | 4096 | ||
extended_fld_device_status | 0807 | Ext dev status | Extended Field Device Status- This provides additional Device Status information | R | BitEnum | 131 |
write_protect_code | 07EE | R/W | Enum | 4096 | ||
loop_current_mode | 0808 | Loop current mode | Loop Current Mode- Indicates whether the loop current is active or fixed (i.e., the device is in multi-drop). | R/W | Enum | 64 |
physical_signaling_codes | 07F1 | R/W | Enum | 4096 | ||
flag_assignment | 07F2 | R/W | Enum | 4096 | ||
loop_current_mode_codes | 07F9 | R/W | Enum | 4096 | ||
extended_device_status_codes | 07FA | R/W | Enum | 4096 | ||
analog_channel_flags | 0802 | R/W | Enum | 4096 | ||
date | 00A6 | Date | Date- Gregorian calendar date that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. | R/W | HartDate | 2048 |
message | 00A4 | Message | Message- Text that is associated with the Field Device. This text can be used by the user in any way. There is no recommended use. | R/W | PackedAscii | 2048 |
device_id | 00A1 | Dev id | Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. | R | Unsigned | 2048 |
hardware_revision | 009F | Hardware rev | Hardware Revision- Revision that corresponds to the electronics hardware of the Field Device. | R | Unsigned | 2048 |
comm_status | 0098 | Communication status | Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. | R | BitEnum | 131 |
final_assembly_number | 00A9 | Final asmbly num | Final Assembly Number- Number that is used for identification purposes, and is associated with the overall Field Device. | R/W | Unsigned | 2048 |
universal_revision | 009C | Universal rev | Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to | R | Unsigned | 128 |
tag | 00A3 | Tag | Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. | R/W | PackedAscii | 2048 |
Name | ID | Label | Description | Type | Access | Class |