Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
pv_sensor_limit_units | 4008 | Pressure unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure | R/W | Enum | 10 |
pv_upper_sensor_limit | 4009 | Pres USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pv_lower_sensor_limit | 400A | Pres LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pv_value | 4001 | R | Float | 10 | ||
pv_value_units | 4000 | PV unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 10 |
pv_damping_value | 400B | PV Damp | R/W | Float | 10 | |
pv_minimum_span | 400C | Pres min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
pv_serial_number | 400D | Pres snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 2048 |
pv_channel | 400E | Input channel | R | Unsigned | 8 | |
percentageValue | 4003 | SV (Percent) | R | Float | 10 | |
percentageUnits | 4002 | % | R | Enum | 10 | |
outputCurrentValue | 4005 | TV (Loop current) | R | Float | 10 | |
outputCurrentUnits | 4004 | Flow Unit | R/W | Enum | 10 | |
temperatureValue | 4007 | QV (Temperature) | Sensor Temperature- Temperature of the sensor that is making the process measurement | R | Float | 10 |
temperatureUnits | 4006 | Temperature Unit | Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. | R/W | Enum | 8 |
flowUnits | 4010 | Flow Unit | Sensor Flow Units- Engineering unit to be displayed with Sensor flow. | R/W | Enum | 8 |
zero_elevation | 4011 | ZERO ELEV. | Measure zero offset value | R/W | Float | 2048 |
regulated_current_zero | 4012 | Zero Current | W | Float | 2048 | |
regulated_current_gain | 4013 | Gain Current | W | Float | 2048 | |
spec_gravity | 4014 | HEAVIER SG | R/W | Float | 2048 | |
spec_gravity_light | 4015 | LIGHTER SG | R/W | Float | 2048 | |
ADC0_value | 4016 | ADC0 Value | R | Float | 2048 | |
ADC1_value | 4017 | ADC1 Value | R | Float | 2048 | |
URV_span_adjustment | 4018 | SPAN URV Value | Edit the full scale adjustment parameter | R/W | Float | 2048 |
device_status | 0097 | Device status | Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process | R | BitEnum | 131 |
Name | ID | Label | Description | Type | Access | Class |