Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
pv_sensor_limit_units | 4008 | Pressure unit | Unidad de variable de dispositivo de campo: Unidad de medición que se mostrará con la representación del valor digital, span mínimo, valor de rango superior, valor de rango inferior, límite inferior del sensor y límite superior del sensor. Presión: Presión del proceso medida con respecto a una presión de referencia | R/W | Enum | 10 |
pv_upper_sensor_limit | 4009 | Pres USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pv_lower_sensor_limit | 400A | Pres LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pv_value | 4001 | R | Float | 10 | ||
pv_value_units | 4000 | PV unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 10 |
pv_damping_value | 400B | PV Damp | R/W | Float | 10 | |
pv_minimum_span | 400C | Pres min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
pv_serial_number | 400D | Pres snsr s/n | Número de serie del sensor: Identifica de manera única el sensor del que se deriva principalmente la representación del valor digital o la variable del dispositivo de campo. | R | Unsigned | 2048 |
pv_channel | 400E | Input channel | R | Unsigned | 8 | |
percentageValue | 4003 | SV (Percent) | R | Float | 10 | |
percentageUnits | 4002 | % | R | Enum | 10 | |
outputCurrentValue | 4005 | TV (Loop current) | R | Float | 10 | |
outputCurrentUnits | 4004 | Flow Unit | R/W | Enum | 10 | |
temperatureValue | 4007 | QV (Temperature) | Temperatura del sensor: Temperatura del sensor que está haciendo la medición del proceso | R | Float | 10 |
temperatureUnits | 4006 | Temperature Unit | Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. | R/W | Enum | 8 |
flowUnits | 4010 | Flow Unit | Sensor Flow Units- Engineering unit to be displayed with Sensor flow. | R/W | Enum | 8 |
zero_elevation | 4011 | ZERO ELEV. | Measure zero offset value | R/W | Float | 2048 |
regulated_current_zero | 4012 | Zero Current | W | Float | 2048 | |
regulated_current_gain | 4013 | Gain Current | W | Float | 2048 | |
spec_gravity | 4014 | HEAVIER SG | R/W | Float | 2048 | |
spec_gravity_light | 4015 | LIGHTER SG | R/W | Float | 2048 | |
ADC0_value | 4016 | ADC0 Value | R | Float | 2048 | |
ADC1_value | 4017 | ADC1 Value | R | Float | 2048 | |
URV_span_adjustment | 4018 | SPAN URV Value | Edit the full scale adjustment parameter | R/W | Float | 2048 |
device_status | 0097 | Device status | Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process | R | BitEnum | 131 |
manufacturer_id | 0099 | Fabricante | Código de identificación del fabricante: Hace referencia a un fabricante específico y suele ser el nombre de la empresa responsable de la fabricación de este dispositivo de campo. | R | Enum | 128 |
device_type | 009A | Model | Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer | R | Enum | 128 |
physical_signaling_code | 00AB | Physicl signl code | Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port | R | Enum | 2048 |
device_flags | 00A0 | Dev flags | Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer | R | BitEnum | 2048 |
private_label_distributor | 00A8 | Distribuidor | Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers | R | Enum | 2048 |
units_code | 07E9 | R/W | Enum | 4096 | ||
write_protect | 00A7 | Write protect | Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. | R | Enum | 2050 |
transfer_function_code | 07EA | R/W | Enum | 4096 | ||
alarm_selection_code | 07EB | R/W | Enum | 4096 | ||
extended_fld_device_status | 0807 | Ext dev status | Extended Field Device Status- This provides additional Device Status information | R | BitEnum | 131 |
write_protect_code | 07EE | R/W | Enum | 4096 | ||
loop_current_mode | 0808 | Loop current mode | Modo de corriente de lazo: Indica si la corriente de lazo es activa o fija (es decir, el dispositivo está en derivaciones múltiples). | R/W | Enum | 64 |
physical_signaling_codes | 07F1 | R/W | Enum | 4096 | ||
flag_assignment | 07F2 | R/W | Enum | 4096 | ||
loop_current_mode_codes | 07F9 | R/W | Enum | 4096 | ||
extended_device_status_codes | 07FA | R/W | Enum | 4096 | ||
analog_channel_flags | 0802 | R/W | Enum | 4096 | ||
date | 00A6 | Fecha | Fecha: Fecha del calendario gregoriano almacenada en el dispositivo de campo. El usuario puede usar esta fecha de cualquier manera. No hay ningún uso específico recomendado. | R/W | HartDate | 2048 |
message | 00A4 | Mensaje | Mensaje: Texto asociado al dispositivo de campo. El usuario puede usar este texto de cualquier manera. No hay ningún uso recomendado. | R/W | PackedAscii | 2048 |
device_id | 00A1 | Dev id | Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. | R | Unsigned | 2048 |
hardware_revision | 009F | Hardware rev | Revisión del hardware: Revisión que corresponde al hardware electrónico del dispositivo de campo. | R | Unsigned | 2048 |
comm_status | 0098 | Communication status | Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. | R | BitEnum | 131 |
final_assembly_number | 00A9 | Final asmbly num | Número de ensamblaje final: Número que se utiliza con fines de identificación y está asociado al dispositivo de campo en general. | R/W | Unsigned | 2048 |
universal_revision | 009C | Universal rev | Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to | R | Unsigned | 128 |
tag | 00A3 | Etiqueta | Etiqueta: Texto asociado a la instalación del dispositivo de campo. El usuario puede usar este texto de cualquier manera. Un uso recomendado es como etiqueta única para una planta que se correlaciona con la etiqueta de dispositivo de campo: esquema de planta, o en un sistema de control. Esta variable también se usa como tipo de dirección de la capa de enlace de datos. | R/W | PackedAscii | 2048 |
Name | ID | Label | Description | Type | Access | Class |