Loading…
Name ID Label Description Type Access Class
inputUnits1 4000 Rnge unit Range Unit- Engineering unit to be displayed with the Upper Range Value and Lower Range Value R/W Enum 32
bytFlowRate_class_cation 407E Class Classificazione - Indica la tabella di espansione dei codici unità utilizzata per una particolare variabile dinamica o dispositivo. R Enum 8
bytFlowRate_update_period 407F Update Period R/W Time 8
fltFlowRateValue 4026 Flow rate digital value Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R/W Float 10
bytFlowRateUnits 4027 Mass flo unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 8
fltFlowRateUpperLimit 4051 USL Valore limite sensore superiore - Definisce il valore massimo utilizzabile per il valore di campo superiore. R/W Float 8
fltFlowRateLowerLimit 4052 LSL Valore limite sensore inferiore - Definisce il valore minimo utilizzabile per il valore di campo inferiore. R/W Float 8
fltFlowRateMinimumSpan 4035 Span Valore intervallo minimo - Definisce la differenza più piccola consentita tra il valore di campo superiore e il valore di campo inferiore. R/W Float 8
fltFlowRateDampingValue 4033 Damping Valore di smorzamento - Costante di tempo di smorzamento applicata sia alla rappresentazione del valore digitale che al valore analogico della rispettiva uscita analogica. Le unità di questa variabile sono sempre in secondi. R/W Float 8
intFlowRateSerialNumber 4080 Mass flo Sensor Serial Number Numero di serie sensore - Identifica in modo univoco il sensore da cui deriva principalmente la rappresentazione del valore digitale o la variabile dispositivo di campo. R/W Unsigned 8
Name ID Label Description Type Access Class