Name ID Label Description Type Access Class
compat_burst_trig_class_1 4F23 Burst Trigger Class R/W Enum 2048
compat_burst_trig_units_1 4F24 Burst Trigger Units R/W Enum 2048
compat_burst_trig_level_1 4F25 Burst Trigger Level Defines the threshold value for the device to begin bursting at the triggered update rate. Within the threshold limits, the device will burst at the default rate. Applicable to rising, falling and windowed trigger modes only. R/W Float 2048
compat_burst_cmd_2 4DE5 Burst Command Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled. R/W Enum 2048
compat_burst_mode_2 4D9C Burst mode Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. R/W Enum 2048
compat_update_per_2 4F26 Update Period Update period for burst message R/W Time 2048
compat_max_update_per_2 4F27 Max Update Period Maxium update period for burst message R/W Time 2048
compat_burst_vars_0_2 4F28 Burst Variable 1 Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. R/W Index 2048
compat_burst_vars_1_2 4F29 Burst Variable 2 Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. R/W Index 2048
compat_burst_vars_2_2 4F2A Burst Variable 3 Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. R/W Index 2048
Name ID Label Description Type Access Class