Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
api_dens_lower_sensor_limit | 508F | API Density Lower Sensor Limit | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
api_dens_minimum_span | 5218 | API Density Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
apidensityClassificationCode | 4E42 | API Density Classification | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
apidensityFamily | 4E43 | API Density Family | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 2048 |
apidensityPDQ | 4DC4 | API Density PDQ | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
apidensityLS | 4E44 | API Density LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 10 |
apidensityStatus | 4E45 | API Density Family Status | Device Family Status- Indicates additional status information on a device variable for a specific device family. | R | BitEnum | 10 |
apidensityUpdatePeriod | 4E46 | API Density Update Period | R | Time | 0 | |
api_vol_flow_digital_value | 41D5 | Flow Rate | The volume flow rate of the petroleum being measured at reference conditions. | R | Float | 10 |
api_vol_flow_digital_units | 521A | API Volume Flow Units | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | R/W | Enum | 32 |
Name | ID | Label | Description | Type | Access | Class |