Name ID Label Description Type Access Class
enable_extern_temp 41E4 Внешняя температура This parameter allows you to enable/disable the external temperature feature R/W Enum 8
static_temperature 41E5 Температура корректировки This parameter allows you to enter a static temperature when using the external temperature feature R/W Float 8
flow_switch_setpoint 418B Setpoint This parameter can be used to trigger a discrete output when the mass flow rate exceeds the configured setpoint. There is a fixed hysteresis of 5% for this setpoint. R/W Float 16
do1_assignment 418C Assignment This parameter identifies which condition the discrete output will act upon. R/W Enum 1024
do1_state 41CD Discrete Output State This parameter identifies the state of the discrete output. R/W Enum 2
do_index 41B3 DO index R/W Index 4096
flow_switch_hysteresis 4563 Hysteresis (0.1-10.0) If the hysteresis is set to 5%, no change of the Discrete Output state occurs when the flow rate is within +-5% of the setpoint. If the setpoint is 100 lb/min and the first reading is below 95 lb/min, the flow switch turns On and will stay On until the flow rate rises above 105 lb/min. At this point it turns Off, and will stay off until the flow rate drops below 95 lb/min. R/W Float 8
chan_a 418D Назначение This parameter identifies the physical output channel to be configured. Channel A is terminals 1 and 2, Channel B is terminals 3 and 4, and Channel C is terminals 5 and 6. R Enum 64
chan_b 418E Назначение This parameter identifies the physical output channel to be configured. Channel A is terminals 1 and 2, Channel B is terminals 3 and 4, and Channel C is terminals 5 and 6. R/W Enum 64
chan_c 418F Назначение This parameter identifies the physical output channel to be configured. Channel A is terminals 1 and 2, Channel B is terminals 3 and 4, and Channel C is terminals 5 and 6. R Enum 64