Loading…
Name ID Label Description Type Access Class
xmtr_tag_2 40F8 External Device Tag 2 This represents the tagname for the device(s) being polled for a process variable used internally for some compensation (e.g. pressure comp). R/W PackedAscii 128
poll_var_1 40F9 Variável 1 sondada (polled): This represents the variable code which will be read via HART for the compensation. R/W Enum 128
poll_var_2 40FA Variável 2 sondada (polled): This represents the variable code which will be read via HART for the compensation. R/W Enum 128
poll_type_code 40F5 Polling Type This parameter identifies which compensation algorithms will be enabled within the device based on the polling being done. R/W Enum 128
update_rate 40FB Update Rate This parameter is the update rate for process variables through the system. Set the update rate to NORMAL for most applications. Set the update rate to SPECIAL if you are using the device in proving applications or extremely short batch applications. Refer to the user's manual for more information before you change this parameter. R/W Enum 2048
update_rate_var 40FC 100 Hz Variable This parameter identifies the transmitter variable that will be updated at 100 Hz. All others will be updated, but at a slower rate. R/W Enum 2048
flow_pres_factor 40FD Flow Pressure Factor Pressure compensation factor applied to flow rate (% change per PSI). R/W Float 8
dens_pres_factor 40FE Density Pressure Factor Pressure compensation factor applied to density (g/Cucm change per PSI). R/W Float 8
zero_pres_factor 40FF Flow Calibration Pressure Pressure at which flow calibration was performed. R/W Float 8
enable_pres_comp 41BC Compensação de pressão This parameter allows you to enable/disable the pressure correction feature R/W Enum 8
Name ID Label Description Type Access Class