Loading…
Name ID Label Description Type Access Class
dens_minimum_span 4044 Dens min span Valor de span mínimo: Define la menor diferencia permitida entre el valor de rango superior y el valor de rango inferior. R Float 8
minv_digital_value 4046 Mass inventory R Float 2
vol_flow_digital_units 4048 Vol flo unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 32
vol_flow_digital_value 4049 Vol flo R Float 2
vol_flow_digital_cutoff 404B Vol flo cutoff The volume flow rate below which the frequency/pulse output indicates zero flow, and below which totalizers stop counting. R/W Float 8
vol_flow_analog_value 404C Vol flo anlog valu R/W Float 66
vol_flow_analog_upper_limit 404D Límite sup. analóg. Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions R Float 66
vol_flow_analog_lower_limit 404E Límite inf. analóg. Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions R Float 66
vol_flow_additional_analog_damping 404F Added damp Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. R/W Float 32
vol_flow_percent_range 4050 Vol flo % rnge Porcentaje de rango: Variable que rastrea la representación del valor digital con respecto al rango definido por el valor de rango inferior y el valor de rango superior, para modos de funcionamiento normales. Las unidades de esta variable siempre son en porcentaje. R Float 34
Name ID Label Description Type Access Class