Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
vol_flow_hzfreq | 4055 | Freq factr | The number of cycles, in Hertz, that equal a proportional flow rate represented by the frequency/pulse output. | R/W | Float | 512 |
vol_flow_hzrate | 4056 | Rate factr | The flow rate that equals a set frequency if the frequency output represents mass or volume flow; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. | R/W | Float | 512 |
vtot_digital_units | 4058 | Vol flo totl unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R | Enum | 32 |
vtot_digital_value | 4059 | Vol totl | R | Float | 2 | |
vtot_hzfreq | 405A | Freq factr | The number of cycles, in Hertz, that equal a proportional flow rate represented by the frequency/pulse output. | R/W | Float | 512 |
vtot_hzrate | 405B | Rate factr | The flow rate that equals a set frequency if the frequency output represents mass or volume flow; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. | R/W | Float | 512 |
vinv_digital_value | 405D | Vol inventory | R | Float | 2 | |
visc_digital_units | 405F | Viscosity unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 32 |
visc_digital_value | 4060 | Viscosity | R | Float | 2 | |
visc_analog_value | 4061 | AO | R/W | Float | 66 | |
Name | ID | Label | Description | Type | Access | Class |