Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
alarm_2_analog_value_1 | 41BD | Event2 anlog valu | R/W | Float | 66 | |
alarm_2_percent_range_1 | 41BE | Event2 % rnge | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
alarm_2_upper_range_value_1 | 41BF | Event2 URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
alarm_2_lower_range_value_1 | 41C0 | Event2 LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
alarm_2_upper_sensor_limit | 408C | Event2 URL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
alarm_2_lower_sensor_limit | 408D | Event2 LRL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
alarm_2_minimum_span | 408E | Event2 min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
mmi_flange_type | 4091 | Flange | Configuration information identifying the flange material used with the sensor. Informational purposes only - does not affect flowmeter operation. | R/W | Enum | 2048 |
liner_matl | 4092 | Liner matl | Configuration information identifying any liner material used with the sensor. Informational purposes only - does not affect flowmeter operation. | R/W | Enum | 2048 |
sensor_model | 4093 | Snsr model | Configuration information identifying the sensor model installed. Informational purposes only - does not affect flowmeter operation. | R/W | PackedAscii | 2048 |
Name | ID | Label | Description | Type | Access | Class |