Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
diff_mass_flow_digital_value | 4308 | Differential Mass Flow | Differential Mass Flow | R | Float | 10 |
analog_damping | 4006 | Added Damping | Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. | R/W | Float | 32 |
mass_flow_digital_damping | 4021 | Flow Damping | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 32 |
serial_number | 4309 | Sensor | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R/W | Unsigned | 2048 |
mass_flow_upper_sensor_limit | 4307 | Mass Flow Upper Sensor Limit | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
mass_flow_lower_sensor_limit | 430A | Mass Flow Lower Sensor Limit | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
mass_flow_minimum_span | 430B | Mass Flow Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
massflowClassificationCode | 430E | Mass Flow Classification | Classification: Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
massflowFamily | 430F | Mass Flow Family | Device Family: Indicates the family (i.e., pressure, temperature, flow, etc.) to which the device belongs. | R | Enum | 2048 |
massflowPDQ | 4310 | Status | Process Data Quality: Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
Name | ID | Label | Description | Type | Access | Class |