Loading…
Name ID Label Description Type Access Class
ednetvolumeinventoryFamily 441D ED Net Volume Inventory Family Device Family: Indicates the family (i.e., pressure, temperature, flow, etc.) to which the device belongs. R Enum 2048
ednetvolumeinventoryPDQ 441E ED Net Volume Inventory PDQ Process Data Quality: Indicates the overall process data quality of the device variable value. R Enum 10
ednetvolumeinventoryLS 441F ED Net Volume Inventory LS Limit Status: Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 10
ednetvolumeinventoryStatus 4420 ED Net Volume Inventory Family Status Device Family Status: Indicates additional status information on a device variable for a specific device family. R BitEnum 10
ednetvolumeinventoryUpdatePeriod 4421 ED Net Volume Inventory Update Period R Time 0
ed_net_mas_flow_digital_value 4422 Net Mass Flow Rate The net mass flow rate of the fluid being measured. R Float 10
ed_net_mas_flow_digital_damping 4423 Flow Damping Valore di smorzamento - Costante di tempo di smorzamento applicata sia alla rappresentazione del valore digitale che al valore analogico della rispettiva uscita analogica. Le unità di questa variabile sono sempre in secondi. R/W Float 32
ednet_mass_flow_minimum_span 4428 Mass Flow Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
ednet_mass_flow_digital_units 4425 Mass Flow Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. R/W Enum 32
ednet_mass_flow_upper_sensor_limit 4426 Mass Flow Upper Sensor Limit Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
Name ID Label Description Type Access Class