Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
mass_flow_analog_upper_limit | 4015 | mA Output Upper Limit | Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions | R | Float | 64 |
mass_flow_analog_lower_limit | 4016 | mA Output Lower Limit | mA output Lower Endpoint Value- Defines the lower endpoint, of the respective mA output, for normal operating conditions. | R | Float | 64 |
mass_flow_additional_analog_damping | 4017 | Added Damping | mA Output Added Damping Value- Damping time constant applied the mA output. The units of this variable are always in seconds. | R/W | Float | 32 |
mass_flow_percent_range | 4018 | Mass Flow Percent Range | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
mass_flow_upper_range_value | 4019 | Mass Flow Upper Range Value | This is the 20mA point. Defines the operational endpoint from which the Analog Value and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines the point above which all high alarms (both analog and digital) for the assigned process variable are activated. | R/W | Float | 32 |
mass_flow_lower_range_value | 401A | Mass Flow Lower Range Value | This is the 12 mA point (Direct) or the 4 mA point (Level-Shifted). Defines the operational endpoint from which the Analog Value and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines the point below which all low alarms (both analog and digital) for the assigned process variable are activated. | R/W | Float | 32 |
mass_flow_digital_damping | 401B | Flow Damping | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective mA output. The units of this variable are always in seconds. | R/W | Float | 32 |
mass_flow_upper_sensor_limit | 4010 | Mass Flow Upper Sensor Limit | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
mass_flow_lower_sensor_limit | 401C | Mass Flow Lower Sensor Limit | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
mass_flow_minimum_span | 401D | Mass Flow Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
Name | ID | Label | Description | Type | Access | Class |