Name ID Label Description Type Access Class
enable_pres_comp 4128 Компенсация давления This parameter allows you to enable/disable the pressure correction feature R/W Enum 8
static_pressure 4129 Давление компенсации This parameter allows you to enter a static pressure when using the pressure correction feature R/W Float 8
enable_extern_temp 412A Внешняя температура This parameter allows you to enable/disable the external temperature feature R/W Enum 8
static_temperature 412B Температура корректировки This parameter allows you to enter a static temperature when using the external temperature feature R/W Float 8
CEQ_Number 412C Спец. для ном.заказа Engineered to Order (ETO) number for the transmitter R Unsigned 2048
feature_key 412D Features The type of log to be reset. R BitEnum 2048
alarm_integer 412E Номер аварийного сигнала This parameter is the number of the alarm. For example, 26 for alarm A26 and 42 for alarm A102. R/W Unsigned 4096
alarm_severity 412F Alarm Severity Assigns a severity level to the currently selected alarm. R/W Enum 4096
Alarm_Status 4130 Alarm Status R Enum 4096
varCount 4131 Count R Unsigned 4096