Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
rt_sigma | 40CD | Standard Deviation | A unitless value which characterizes the amount of deviation between readings during an Auto Zero operation. | R | Float | 10 |
fault_index | 40CE | Output Type | R/W | Index | 4096 | |
LMV_fault_timeout | 40D0 | Время задержки в случае неисправности | This parameter defines the number of seconds for which all outputs will hold their last measured value prior to going to the configured fault state. The default is zero seconds. | R/W | Unsigned | 12 |
ao_1_fault_code | 40D3 | Действие сбоя | Минимальное значение при измерении: токовые выходы, показывающие поток, переходят на настроенный предел. Максимальное значение при измерении: токовые выходы переходят на настроенный предел. Внутренний ноль: выходы потока показывают нулевой поток. | R/W | Enum | 12 |
ao_1_fault_level | 40D5 | Fault Level (Direct) | This parameter allows you to select the lower or upper mA output level that will indicate a fault condition. For a 12-20 mA output (Direct), the range is 11.5 to 11.8 mA for downscale or 20.5 to 22.0 for upscale. For a 4-20 mA output (Level-Shifted), the range is 3.0 to 3.6 mA for downscale or 21.0 to 24.0 for upscale. | R/W | Float | 66 |
ao_1_fault_level_4_20 | 40D7 | Уровень ошибки (изолирующий адаптер) | This parameter allows you to select the lower or upper mA output level that will indicate a fault condition. For a 12-20 mA output (Direct), the range is 11.5 to 11.8 mA for downscale or 20.5 to 22.0 for upscale. For a 4-20 mA output (Level-Shifted), the range is 3.0 to 3.6 mA for downscale or 21.0 to 24.0 for upscale. | R/W | Float | 66 |
dig_comm_fault_code | 40D9 | Действие сбоя цифровой связи | This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected) | R/W | Enum | 12 |
density_for_cal | 40DE | R/W | Float | 4096 | ||
point_code | 40DF | R/W | Unsigned | 4096 | ||
densityfd_for_cal | 40E0 | R/W | Float | 4096 | ||
Name | ID | Label | Description | Type | Access | Class |