Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
live_zero_vol_flow_additional_analog_damping | 40A1 | Added Damping | mA Output Added Damping Value- Damping time constant applied the mA output. The units of this variable are always in seconds. | R/W | Float | 32 |
live_zero_vol_flow_percent_range | 40A2 | Mass flo % rnge | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
live_zero_vol_flow_upper_range_value | 40A3 | Mass flo URV | This is the 20mA point. Defines the operational endpoint from which the Analog Value and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines the point above which all high alarms (both analog and digital) for the assigned process variable are activated. | R/W | Float | 32 |
live_zero_vol_flow_lower_range_value | 40A4 | Mass flo LRV | This is the 12 mA point (Direct) or the 4 mA point (Level-Shifted). Defines the operational endpoint from which the Analog Value and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines the point below which all low alarms (both analog and digital) for the assigned process variable are activated. | R/W | Float | 32 |
live_zero_vol_flow_upper_sensor_limit | 40A5 | Mass flo URL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 8 |
live_zero_vol_flow_lower_sensor_limit | 40A6 | Mass flo LRL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
live_zero_vol_flow_minimum_span | 40A7 | Mass flo min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
input_volt_digital_units | 40A9 | Input voltage unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | R | Enum | 32 |
input_volt_digital_value | 40AA | Core Processor Input Voltage | Input voltage is the current power input. | R | Float | 10 |
mmi_flange_type | 40AE | Sensor Flange | Configuration information identifying the flange material used with the sensor. Informational purposes only - does not affect flowmeter operation. | R/W | Enum | 2048 |