Loading…
Name ID Label Description Type Access Class
level_units 4001 Units Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 8
level 4002 Level Level of material in vessel R Float 34
level_percent_range 400A %Output Porcentaje de rango: Variable que rastrea la representación del valor digital con respecto al rango definido por el valor de rango inferior y el valor de rango superior, para modos de funcionamiento normales. Las unidades de esta variable siempre son en porcentaje. R Float 66
distance 4015 Distance Distance measurement includes Sensor Offset value. R Float 34
quality 4016 Quality Quality of signal reflection, best values are between 20 and 90. R Unsigned 34
echo_amplitude 4017 Echo Amplitude Amplitude of target peak; Factory parameter, displayed for diagnostic purposes only. R Float 34
rate_of_change 4018 ROC per minute Factory parameter, displayed for diagnostic purposes only. R Float 34
scatter 4019 Scatter Factory parameter, displayed for diagnostic purposes only. R Unsigned 34
rate 401A Rate Factory parameter, displayed for diagnostic purposes only. R Unsigned 34
level_minimum_span 4006 Minimum Span Minimum difference between 4mA and 20mA set points R Float 32
Name ID Label Description Type Access Class