Name ID Label Description Type Access Class
damping 4014 Damping Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 8
current 4015 Loop Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 66
sysfault 4016 System Fault System Fault defines how the Analog Output will respond when the transmitter detects a system fault. R/W Enum 65
percent_range 4017 % Output Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 66
transfer_function 1F84 Xfer fnctn R Enum 32
lvl_set4mA 4018 Lvl 4 mA Set Point Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 64
lvl_set20mA 4019 Lvl 20 mA Set Point Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 64
vol_set4mA 401A Vol 4 mA Set Point Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 64
vol_set20mA 401B Vol 20 mA Set Point Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 64
flow_set4mA 401C Flow 4 mA Set Point Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 64
Name ID Label Description Type Access Class