Loading…
Name ID Label Description Type Access Class
range_i_1 4006 Range I R/W Enum 64
LevelGain 4008 Gain Gain of the level pulse (read only) R/W Enum 2048
fThreshold 40D2 Threshold Threshold Level (mV) R/W Float 34
fDistThreshold 40D4 Dist (mm) Dist Threshold (mm) R/W Float 8
LevSignalAmp 401E Lev Sign. Level Signal Amplitude (read only) R/W Float 34
LevSignalGain 401F Gain Gain of the level pulse (read only) R/W Unsigned 34
ApplicationType 403D Application Type Allow to the BM102 to know the process configuration (1 or 2 liquids) R/W Enum 2048
fEpsilonR 40B8 Epsilon R Lower Epsilon R value of the 2 liquids R/W Float 8
pair_index 400C R/W Index 4096
Tank_height 409A Tank Height This function is the base of indication and current outputs reference. It is the distance from the flange to the bottom of the tank. However, it can be configured as the "probe length". The minimum and maximum values are (Probe Length) and 200 ft (60 m) respectively. The factory default value is per your sales order. NOTE: The BM102 does not measure beyond its probe length. R/W Float 8
Name ID Label Description Type Access Class