Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
range_i_1 | 4006 | Range I | R/W | Enum | 64 | |
LevelGain | 4008 | Gain | Gain of the level pulse (read only) | R/W | Enum | 2048 |
fThreshold | 40D2 | Threshold | Threshold Level (mV) | R/W | Float | 34 |
fDistThreshold | 40D4 | Dist (mm) | Dist Threshold (mm) | R/W | Float | 8 |
LevSignalAmp | 401E | Lev Sign. | Level Signal Amplitude (read only) | R/W | Float | 34 |
LevSignalGain | 401F | Gain | Gain of the level pulse (read only) | R/W | Unsigned | 34 |
ApplicationType | 403D | Application Type | Allow to the BM102 to know the process configuration (1 or 2 liquids) | R/W | Enum | 2048 |
fEpsilonR | 40B8 | Epsilon R | Lower Epsilon R value of the 2 liquids | R/W | Float | 8 |
pair_index | 400C | R/W | Index | 4096 | ||
Tank_height | 409A | Tank Height | This function is the base of indication and current outputs reference. It is the distance from the flange to the bottom of the tank. However, it can be configured as the "probe length". The minimum and maximum values are (Probe Length) and 200 ft (60 m) respectively. The factory default value is per your sales order. NOTE: The BM102 does not measure beyond its probe length. | R/W | Float | 8 |