Name ID Label Description Type Access Class
sensor_serial_number 400A PV Snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 2048
level_value 400D Level Level - The total product measurement of the device R Float 10
level_units 400E This is the UNIT of measure for the process variable of the device and provides a basis for all of the setup functions. Selectable engineering UNITS include: inches, feet, meters, millimeters and centimeters. R/W Enum 8
UnitsNone 400F Units R Enum 2048
lin_level_value 4010 Linearized Level Linearized Level - The output of the linearization table based on Level R Float 10
ULDMode 42AA Ultra Low Dielectric Mode Used only when dielectric constant of material is between 1.3 and 2.3. R/W Enum 2048
sw_revision_date 4019 Software Revision Date Software Revision Date- Gregorian calendar date denoting the date of Software Release R/W HartDate 2048
probe_type 401A Probe Type This function will help adjust the transmitter setting for the installed configuration. Certain aspects of the transmitter setup will be adjusted to conform to the probe type selected. Selectable probe types include: Single Rod/Cable, Dual Rod/Cable or Coaxial. Select only the type of probe mounted to the MT5xxx transmitter. Failure to set the correct probe type could result in measurement errors. R/W Enum 2048
mounting_type 401B Mounting Type Mounting configurations will affect probe types in different ways. A sensor mounted on a nozzle whose length is greater than its width could cause a reduced signal capacity which must be accounted for by the MT5xxx. The MOUNTING TYPE corresponding to the installation must be entered correctly. The MOUNTING TYPE should fall into one of the categories listed below: PLATE - a flat surface roof or metal disk used for signal launch COUPLING PLATE - a coupling or nipple fitting welded to a flat ceiling or launch plate. NOZZLE/FLANGE H>S - A nozzle with a greater height than diameter. NOZZLE/FLANGE H R/W Enum 2048
nozzle_length 401C Nozzle Length Also known as nozzle blanking distance, this setting allows the transmitter to ignore anything within the designated distance. The distance will be in the units designated in the UNITS parameter. At a minimum, enter the length of the mounting nozzle from the face of the sensor to the ceiling of the tank. Additional distance can be added in order to ignore unwanted false reflections. 2CAUTION: This entry will allow the transmitter to ignore any reading in the designated area including the level you are measuring if it rises to this range. 2WARNING - Adjustment of this parameter may disturb settings in your Extended Parameters. Please verify Extended Parameters are set correctly for the application R/W Float 2048
Name ID Label Description Type Access Class