Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
flange_type | 139A | Flange Type | Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 2048 |
flange_material | 177C | Flnge Matl | Flange Material- Construction material of flange type. | R/W | Enum | 2048 |
o_ring_material | 139B | O Ring Matl | O Ring Material- Construction material of a seal that exists between the module and flange. | R/W | Enum | 2048 |
meter_installation | 139C | Meter Type | Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. | R/W | Enum | 256 |
drain_vent_material | 1780 | Drain Vent Matl | Drain Vent Material- Construction material of a removable plug that exists on the flange type that can be opened temporarily to remove unwanted process from the sensor area | R/W | Enum | 2048 |
remote_seal_type | 139D | RS Type | Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. | R/W | Enum | 2048 |
remote_seal_fill_fluid | 4004 | RS Fill Fluid | Remote Seal Fill Fluid- Fluid material in the device remote seal. | R/W | Enum | 2048 |
remote_seal_isolator_material | 177E | RS Isoltr Matl | Remote Seal Isolator Material- Construction material of a part of the remote seal type that comes in contact with the process material. This is only unambiguous if 1 remote seal is installed. | R/W | Enum | 2048 |
number_of_remote_seals | 139F | Num Remote Seal | Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed. | R/W | Enum | 2048 |
module_fill_fluid | 139E | Fill Fluid | Sensor Fill Fluid- Fluid material in the module. | R/W | Enum | 2048 |