Name ID Label Description Type Access Class
write_protect 00A7 Write protect Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. R Enum 2048
private_label_distributor 00A8 Distribuidor Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers R Enum 2048
final_assembly_number 00A9 Final asmbly num Número de ensamblaje final: Número que se utiliza con fines de identificación y está asociado al dispositivo de campo en general. R/W Unsigned 2048
xmtr_specific_status_0 0FB5 Status group 1 Estado específico del dispositivo de campo Byte 1: Datos que tiene el estado del dispositivo de campo información relativa a: fallos/advertencias/estado de los procesos. R BitEnum 2051
xmtr_specific_status_1 0FB6 Status group 2 Estado específico del dispositivo de campo Byte 2: Datos que tiene el estado del dispositivo de campo información relativa a: fallos/advertencias/estado de los procesos. R BitEnum 2051
burst_command_number 0FFD Burst option Opción de ráfaga: Selecciona las variables a las que se aplicarán ráfagas si el modo de ráfaga está activado. W Enum 128
burst_mode_select 0FFF Burst mode Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. W Enum 128
pressure_units 138D Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Enum 8
pressure_value 138E Pres Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 10
pressure_percent_range 138F PV % Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 34
Name ID Label Description Type Access Class