Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
FLOW_MassFlowScale_1 | 40A6 | Mass flow factor | Enter the multiplication factor to apply to the mass flow value. | R/W | Float | 2048 |
FLOW_MassFlowStatus_1 | 40A7 | Mass flow status | R | Unsigned | 2 | |
FLOW_MaxMeasVarValue_1 | 40A8 | High value partial filled pipe detection | Enter the upper limit value for the selected process variable. If the measured value exceeds the limit value, diagnostic message "862 Partly filled pipe" is generated. Additional information: This setting applies only if the "Density unit" parameter is set to °API. | R/W | Float | 2048 |
Unit_Variable_FLOW_MaxMeasVarValue_1 | 40AA | R | Enum | 2048 | ||
FLOW_MeasVarMonitoringSelector_1 | 40A9 | Partially filled pipe detection | Select process variable for detection of an empty or partially filled pipe. NOTE Due to low density, deactivate partially filled pipe detection for a gas! | R/W | Enum | 2048 |
FLOW_MinMeasVarValue_1 | 40AD | Low value partial filled pipe detection | Enter the lower limit value for the selected process variable. If the measured value drops below the limit value, diagnostic message "862 Partly filled pipe" is generated. Additional information: - This setting applies only if the "Density unit" parameter is not set to °API. - The lower limit value must be lower than the upper limit value ("High value partial filled pipe detection" parameter). | R/W | Float | 2048 |
Unit_Variable_FLOW_MinMeasVarValue_1 | 40AE | R | Enum | 2048 | ||
FLOW_PositivZeroReturn_1 | 40B1 | Flow override | Stops the measuring process. Can be used for example when cleaning the pipeline. | R/W | Enum | 2048 |
FLOW_PressureShockSuppression_1 | 40B2 | Pressure shock suppression | Enter time frame for signal suppression (= pressure shock suppression active), for example to prevent the device from registering flow movements in the pipe when a valve is closed. Additional information: Pressure schock suppression is activated when the flow rate drops below the on value for low flow cutoff. Output values when pressure shock suppression is active: - Flow: 0 - Totalizer: Last valid value Pressure shock suppression is deactivated when: - The time frame specified has elapsed and - Flow exceeds the off value for low flow cutoff | R/W | Float | 2048 |
FLOW_RefDensity_1 | 40B3 | Calculated reference density | Displays the reference density currently calculated. Additional information: The applicable unit of measure is specified in the "System units" submenu. | R | Float | 2 |