Name ID Label Description Type Access Class
FLOW_MassFlowScale_1 40A6 Mass flow factor Enter the multiplication factor to apply to the mass flow value. R/W Float 2048
FLOW_MassFlowStatus_1 40A7 Mass flow status R Unsigned 2
FLOW_MaxMeasVarValue_1 40A8 High value partial filled pipe detection Enter the upper limit value for the selected process variable. If the measured value exceeds the limit value, diagnostic message "862 Partly filled pipe" is generated. Additional information: This setting applies only if the "Density unit" parameter is set to °API. R/W Float 2048
Unit_Variable_FLOW_MaxMeasVarValue_1 40AA R Enum 2048
FLOW_MeasVarMonitoringSelector_1 40A9 Partially filled pipe detection Select process variable for detection of an empty or partially filled pipe. NOTE Due to low density, deactivate partially filled pipe detection for a gas! R/W Enum 2048
FLOW_MinMeasVarValue_1 40AD Low value partial filled pipe detection Enter the lower limit value for the selected process variable. If the measured value drops below the limit value, diagnostic message "862 Partly filled pipe" is generated. Additional information: - This setting applies only if the "Density unit" parameter is not set to °API. - The lower limit value must be lower than the upper limit value ("High value partial filled pipe detection" parameter). R/W Float 2048
Unit_Variable_FLOW_MinMeasVarValue_1 40AE R Enum 2048
FLOW_PositivZeroReturn_1 40B1 Flow override Stops the measuring process. Can be used for example when cleaning the pipeline. R/W Enum 2048
FLOW_PressureShockSuppression_1 40B2 Pressure shock suppression Enter time frame for signal suppression (= pressure shock suppression active), for example to prevent the device from registering flow movements in the pipe when a valve is closed. Additional information: Pressure schock suppression is activated when the flow rate drops below the on value for low flow cutoff. Output values when pressure shock suppression is active: - Flow: 0 - Totalizer: Last valid value Pressure shock suppression is deactivated when: - The time frame specified has elapsed and - Flow exceeds the off value for low flow cutoff R/W Float 2048
FLOW_RefDensity_1 40B3 Calculated reference density Displays the reference density currently calculated. Additional information: The applicable unit of measure is specified in the "System units" submenu. R Float 2
Name ID Label Description Type Access Class