Loading…
Name ID Label Description Type Access Class
C4W_InputPressure_1 4037 External pressure Displays the pressure read from the external source. R Float 2
C4W_InstallationAnglePitch_1 4039 Installation angle pitch Enter the installation angle pitch in degrees. R/W Float 2048
C4W_InstallationAngleRoll_1 403A Installation angle roll Enter the installation roll angle in degrees. R/W Float 2048
C4W_MeasCarrTubeTemp_1 403B MeasCarrTubeTemp R Enum 2048
C4W_MeasTubeDampingUpperLimit_1 403C Limit value measuring tube damping R/W Float 2048
C4W_MeasurementTemperatureMode_1 403D Temperature mode Select the temperature mode for temperature compensation. R Enum 2048
C4W_MediumInhomogenCutOffGas_1 403E Cut off inhomogeneous wet gas Enter cut off value for inhomogeneous wet gas applications. Below this value the "Index inhomogeneous medium" is set to 0. R/W Float 2048
C4W_MediumInhomogenCutOffLiquid_1 403F Cut off inhomogeneous liquid Enter cut off value for inhomogeneous liquid applications. Below this value the "Index inhomogeneous medium" is set to 0. Additional information: This parameter is used for entrained gas in liquid applications or solids in liquid applications. R/W Float 2048
C4W_MediumInhomogenIndex_1 4040 Index inhomogeneous medium Indicates the severity of the second phase. For applications with entrained gas for example, the index describes the relative amount of entrained gas in the liquid. If there is no entrained gas in the liquid, the value is 0, and for very high levels of gas volume (associated with severe slug flow, for example), the value exceeds 10. Additional information: - The index increases with an increase in the second phase, such as gas volume in a liquid, but scaling is not linear (i.e. no 1:1 correlation of index to gas volume fraction), and with increased flow speed, which results in greater homogeneity, the index value decreases - The index will not saturate with excessive second phase. - The diagnostic is repeatable under the same conditions, and thus can be used to better understand process conditions and the relative severity of the second phase. - This index can also be used to determine the relative level of solids in a liquid or the relative level of a liquid phase in a wet gas. R Float 2
C4W_MediumInhomogenSuspBubCutOff_1 4041 Cut off suspended bubbles Enter cut off value for suspended bubbles. Below this value the Index suspended bubbles is set to 0. R/W Float 2048
Name ID Label Description Type Access Class