Name ID Label Description Type Access Class
FlowUpperRangeValue 408D Set URV Enter a flow / pressure value for the upper current value (20mA) R/W Float 32
FourMaCurrentLimit 408E Set min. current Enter lower current limit / Options: 3.8mA; 4.0mA R/W Enum 32
GenericDeviceType 4052 Device name str. R Enum 32
HartDate 408F HART date Enter the date of the last configuration change R/W PackedAscii 32
HartDescriptor 4090 Descriptor Enter the tag description R/W PackedAscii 32
HartMessage 4091 HART message Enter a message R/W PackedAscii 32
HeightUnitEasy 4092 Height unit Selection of height unit / The measured pressure is converted R/W Enum 32
HighCalOffsetCurrent 4094 Offset trim 20mA Displays the difference between 20mA and the value entered for the CURRENT TRIM 20mA paramter R/W Float 32
HighCalWrittenCurrent 4095 Curr. trim 20mA Enter current value for the upper point of the current output trim line R/W Float 32
HighLevelEasy 4096 Full calib. Enter a level, volume, mass or percentage value for the upper calibration point R/W Float 32
HighLevelEasyWet 4097 Full calib. Enter level value for the upper calibration point (tank full) R/W Float 32
HighLevelPressureEasy 409A Full pressure Enter the pressure value for the upper calibration point R/W Float 32
LastAlarmInfo_io 409B Last diag. code Displays the last message that occured and is elimitated R Enum 2
LastAlarmInfo0 409C Last diag. 1 Displays the last messages that occured and are elimitated R Enum 2
LastAlarmInfo1 409D Last diag. 2 Displays the last messages that occured and are elimitated R Enum 2
LastAlarmInfo2 409E Last diag. 3 Displays the last messages that occured and are elimitated R Enum 2
LastAlarmInfo3 409F Last diag. 4 Displays the last messages that occured and are elimitated R Enum 2
LastAlarmInfo4 40A0 Last diag. 5 Displays the last messages that occured and are elimitated R Enum 2
LastAlarmInfo5 40A1 Last diag. 6 Displays the last messages that occured and are elimitated R Enum 2
LastAlarmInfo6 40A2 Last diag. 7 Displays the last messages that occured and are elimitated R Enum 2
LastAlarmInfo7 40A3 Last diag. 8 Displays the last messages that occured and are elimitated R Enum 2
LastAlarmInfo8 40A4 Last diag. 9 Displays the last messages that occured and are elimitated R Enum 2
LastAlarmInfo9 40A5 Last diag. 10 Displays the last messages that occured and are elimitated R Enum 2
Level100PercentValueEasy 40A6 Full height Enter the height value for the upper calibration point (tank full) R/W Float 32
LevelAdjustDensityEasy 40A7 Adjust density Enter the density of a fluid / The measured pressure is converted to a height R/W Float 32
LevelAdjustment 4093 Level selection Selection of the level mode R/W Enum 32
LevelAdjustModeEasy 4098 Calibration mode Selection of the calibration mode / Wet or dry calibration R/W Enum 32
LevelAvailable 40A8 Level option Displays the availability of the operating mode level R Enum 32
LevelMeasurementDensityEasy 4033 Process density Enter a new density value for density correction R/W Float 32
LevelOffsetEasy 40A9 Empty height Enter the height value for the lower calibration point (tank empty) R/W Float 32
LevelSimulationValue 40AA Sim. level Enter simulation value R/W Float 32
LevelTankDescription 40AB Tank description Enter a tank description for simulation needs R/W PackedAscii 32
LevelUnit 40AC ENG. UNIT LEVEL R Enum 32
LinearisationTableEdit 40AD Edit table Selection of the function for the linearisation table R/W Enum 32
LinearisationTableIndex 40B0 Line-numb: Confirmation of the value displayed R/W Unsigned 32
LinearisationTableMode 40AE Lin. mode Selection of the entry mode for the linearisation table R/W Enum 32
LinearisationTableXValue 40B3 X-val: X-Value of linenumber / The hydrostatic pressure present is displayed and saved by confirming the Y-value R/W Float 32
LinearisationTableYValue 40B4 Y-val: Y-Value of linenumber / Depending on the settings of the parameter UNIT AFTER LIN., enter the volume, mass or % value R/W Float 32
LinearLevelMax 40B5 LEVEL MAX R/W Float 32
LinearLevelMin 40B6 LEVEL MIN R/W Float 32
LongTag 40B7 Device tag Enter a tag number R/W ASCII 32
LoopCurrentMode 40B8 Current mode Enables and disables the ''Multidropmode'' R/W Enum 32
LowCalOffsetCurrent 40B9 Offset trim 4mA Displays the difference between 4mA and the value entered for the CURRENT TRIM 4mA parameter R/W Float 32
LowCalWrittenCurrent 40BA Curr. trim 4mA Enter current value for the lower point of the current output trim line R/W Float 32
LowerRangeValue 40BB Set LRV R/W Float 32
LowLevelEasy 40BC Empty calib. Enter a level, volume, mass or percentage value for the lower calibration point R/W Float 32
LowLevelEasyWet 40BD Empty calib. Enter level value for the lower calibration point (tank empty) R/W Float 32
LowLevelPressureEasy 40BE Empty pressure Enter the pressure value for the lower calibration point R/W Float 32
LSDisplayLanguage 407A R Enum 32
LSDisplayMainline2Content 407C R Enum 32
Name ID Label Description Type Access Class