Loading…
Name ID Label Description Type Access Class
flow_sensor_value 4001 Flo Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 10
flow_sensor_units 4002 Vol flo unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 8
flow_sensor_upper_limit 4003 Upr trim pt limit Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R/W Float 8
flow_sensor_lower_limit 4004 Lor trim pt limit Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R/W Float 8
flow_sensor_minimum_span 4005 Vol flo min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R/W Float 8
flow_sensor_damping_value 4006 Flo damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 8
analog_value 4007 Vol flo anlog valu Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 66
analog_alarm_code 4008 AO Alrm typ Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R/W Enum 64
input_percent_range 4009 Vol flo % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
input_transfer_function 400A Xfer fnctn Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. R Enum 32
Name ID Label Description Type Access Class