Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
module_type_code | 177B | Meas typ | Measurement Type- Type of measurement application this Field Device is intended to be used with | R | Enum | 2048 |
sensor_a_lower_sensor_trim_point | 1774 | Pres snsr LST pt | Lower Sensor Trim Point- Applied process pressure at which the last low sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. | R/W | Float | 8 |
sensor_a_upper_sensor_trim_point | 1776 | Pres snsr UST pt | Upper Sensor Trim Point- Applied process pressure at which the last upper sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. | R/W | Float | 8 |
flange_material | 177C | Flnge matl | Flange Material- Construction material of flange type | R | Enum | 2048 |
remote_seal_isolator_material | 177E | RS isoltr matl | Remote Seal Isolator Material- Construction material of a part of the remote seal type that comes in contact with the process material. This is only unambiguous if 1 remote seal is installed. | R | Enum | 2048 |
module_isolator_material | 177F | Isoltr matl | Sensor Isolator Material- Construction material of a part of the module type that comes in contact with the process material | R | Enum | 2048 |
drain_vent_material | 1780 | Drain vent matl | Drain Vent Material- Construction material of a removable plug that exists on the flange type that can be opened temporarily to remove unwanted process from the sensor area. | R/W | Enum | 2048 |
Name | ID | Label | Description | Type | Access | Class |