Loading…

Variable Name: xmtr_specific_status_8

Variable ID: 0x0FBD

Variable Label: Alarm status 1

Variable Help: Byte di stato specifico dispositivo di campo 17 - Dati contenti le informazioni sullo stato del dispositivo di campo relative a: guasti/avvertimenti/stato del processo.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Mass flo L alm
0x0002 Mass flo H alm
0x0004 Vol flo L alm
0x0008 Vol flo H alm
0x0010 Dens L alm
0x0020 Dens H alm
0x0040 Temp L alm
0x0080 Temp H alm

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
180 4274 read_history_absolute

Variable Write Command List

None