Loading…
Loading…
Variable Name: diag_option
Variable ID: 0x418D
Variable Label: Diag Option
Variable Help: Bit mask for Alarm against Diag Error Status.
Variable Handling: R/W
Variable Class:
Variable Size: 2
Variable DataType: BitEnum
Variable Enum Value | Variable Enum Text |
---|---|
0x4000 | Flg Temp High Alarm |
0x2000 | Flg Temp Low Alarm |
0x1000 | ILBD over Range |
0x0800 | Invalid Ref DP |
0x0200 | Invalid Ref Pres 1 |
0x0400 | Invalid Ref Pres 2 |
0x0100 | Invalid Ref BlkF |
0x0080 | B Blocking |
0x0040 | Pres 1 Side Blocking |
0x0020 | Pres 2 Side Blocking |
0x0010 | Large Fluct Pres 1 |
0x0008 | Large Fluct Pres 2 |
0x0004 | A Blocking |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
200 | 4189 | read_us16_values |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
201 | 418E | write_us16_values |