Loading…

Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 PV Analog Channel Saturated
0x0008 PV Analog Channel Fixed
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 4038 read_sp_percent_of_range_and_engr_output
129 4039 read_amp_temp_and_do_and_flg_temp_val
130 4040 read_output_configuration
143 4053 read_tz_cmp_configuration_and_flg_temp_configuration
146 405A read_digital_output_configuration
148 405E read_pres_n_sp_hl_alarm_configuration
152 4069 read_disp_configuration
154 406D read_engr_unit_and_range
157 4072 read_sc_enbl_n_num_of_pts_n_start_end_pts
159 407A read_sc_point_values_1
161 4082 read_sc_point_values_2
163 408A read_sc_point_values_3
168 4099 read_press_trim_points_and_devs
169 409C read_sp_trim_points_and_devs
170 40A1 read_trim_date_and_desc
177 40AA read_serial_no_and_device_info
178 40AC read_soft_rev_and_device_info
179 40B0 read_ms_code_1
180 40B1 read_ms_code_2
181 40B2 read_ms_code_3
183 40B4 read_auto_recover
185 40B7 read_si_option
187 40B9 read_test_mode_data
194 40D3 read_trim_who_and_loc
196 40D7 read_cap_temp_hl_alarm_configuration
200 40DB read_us16_values
200 40DB read_us16_values
202 40E1 read_float_values
202 40E1 read_float_values
202 40E1 read_float_values
202 40E1 read_float_values
204 40F7 diag_pack
204 40F7 diag_pack
204 40F7 diag_pack
204 40F7 diag_pack
210 40FC read_packed_ascii_values
212 40FF read_diag_value_and_status
212 40FF read_diag_value_and_status
212 40FF read_diag_value_and_status
248 4119 read_joker_password_log
249 411B read_passwords_for_wrt_protect
135 4164 read_static_press_configuration
173 4168 read_static_press_range_limits
228 4186 read_model
252 4188 read_optional_function_password
198 4120 read_us8_values
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
54 1057 read_device_variable_information
90 115E read_real_time_clock
105 1063 read_burst_mode_configuration

Variable Write Command List

None