Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label: Response code

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Operazione completata
0x0002 Selezione non valida
0x0003 Value was too high
0x0004 Value was too low
0x0005 Byte dati ricevuti insufficienti
0x0006 Errore specifico dispositivo di campo
0x0007 In modalità protezione scrittura
0x0010 Accesso limitato
0x0020 Occupato
0x0021 Risposta ritardata avviata
0x0022 Risposta ritardata in esecuzione
0x0023 Risposta ritardata non completata
0x0024 Conflitto risposta ritardata
0x0040 Comando non implementato

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
523 1303 read_condensed_status_map
523 1303 read_condensed_status_map
523 1303 read_condensed_status_map
523 1303 read_condensed_status_map
128 400E read_device_name
129 4012 read_passport_data
130 4014 read_sensor_info
131 4017 read_module_name
137 4018 read_dispenser_data
180 4020 read_additive_calibration_value
182 4023 read_multiplicative_calibration_value
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables
50 1052 read_device_variable_assignments
54 1057 read_device_variable_information
60 0FE5 read_analog_output_and_percent_of_range
63 104B read_analog_channel_information
70 1022 read_analog_channel_endpoint_values
80 1046 read_device_variable_trim_point
81 104A read_device_variable_trim_guidelines
95 11DD read_device_communication_statistics

Variable Write Command List