Variable Name: alarm_mode

Variable ID: 0x4024

Variable Label: alarm mode

Variable Help:

Variable Handling: R/W

Variable Class: Device

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Alarm Set Value ( OFF:High, ON:Low )
0x0002 Reflesh ( OFF:Auto, ON:Hold )
0x0004 Alarm Function ( OFF:yes, ON:non )
0x0008 DO Output ( OFF:yes, ON:non )

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
150 4027 read_alarm_and_special_mode

Variable Write Command List

Command Number Command ID Command Name
151 4028 write_alarm_mode