Loading…

Variable Name: KDGM_target_number_of_pulses

Variable ID: 0x4042

Variable Label: Target Pulses P044

Variable Help: Target Pulses P044 No of pulses - The number of cycles in the ultrasonic burst. The typical value is 10 cycles

Variable Handling: R/W

Variable Class: Correction

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x00FD AUTOMATIC
0x0004 4
0x0005 5
0x0006 6
0x0007 7
0x0008 8
0x0009 9
0x000A 10
0x000B 11
0x000C 12
0x000D 13
0x000E 14
0x000F 15
0x0010 16
0x0011 17
0x0012 18
0x0013 19
0x0014 20
0x0015 21
0x0016 22
0x0017 23
0x0018 24
0x0019 25
0x001A 26
0x001B 27
0x001C 28
0x001D 29
0x001E 30
0x001F 31
0x0020 32

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
140 4090 KDGM_read_protected_parameters

Variable Write Command List

Command Number Command ID Command Name
145 4094 KDGM_write_target_number_of_pulses