Loading…

Variable Name: response_code

Variable ID: 0x0096

Variable Label:

Variable Help: Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself.

Variable Handling: R/W

Variable Class: Diagnostic | HART

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 Success

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 4048 read_additional_data
132 4051 read_sensor_data
138 4057 read_zero_reference_data
144 405E read_span_calibration_data
160 4065 read_output_data
151 406E read_dates_of_span_calibrations
155 4075 read_lab_values
161 407A read_attenuations
162 407D read_control_unit_diagnostics
163 4081 read_senor_diagnostics
164 4084 read_senor_system_data
165 4089 read_external_inputs
166 408C read_custom_setup
176 409B read_relay_1_mode_setpoints
182 40AF read_relay_2_mode_setpoints
188 40B0 read_alarm_fault_allocations
197 40BB read_totaliser_and_display_configuration
210 40CD read_control_unit_data
215 40D6 read_sensor_data_and_hmi_configuration
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
12 00B4 read_message
13 00B5 read_tag_descriptor_date
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
16 00B8 read_final_assembly_number
48 0FCE read_additional_transmitter_status

Variable Write Command List

None