Variable Name: rs485_stop

Variable ID: 0x40DC

Variable Label: RS485 Stop Bits

Variable Help: Dieser Parameter definiert die Anzahl der Stop bits für die RS485 Schnittstelle.

Variable Handling: R/W

Variable Class:

Variable Size: 1

Variable DataType: Unsigned

Variable Display Format: |en|1d

Variable Edit Format: |en|1d

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
222 417D read_rs485_setup_params

Variable Write Command List

Command Number Command ID Command Name
223 417E write_rs485_setup_params