Loading…

变量名称: dig_comm_fault_code

变量ID: 0x40A7

变量标签: Comm Fault ind.

变量描述: This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected)

变量处理: 读/写

变量分类: 服务 | Correction

变量长度: 1

变量数据类型: 枚举

变量枚举值 变量枚举文本
0x0000 Upscale
0x0001 Downscale
0x0002 IntZero-All 0
0x0003 Not-a-Number
0x0004 IntZero-Flow 0
0x0005

变量显示格式:

变量编辑格式:

变量单位:

变量最大值: N/A

变量最小值: N/A

变量读取命令列表

变量写入命令列表