Loading…
Loading…
Variable Name: Word_422
Variable ID: 0x412B
Variable Label: Status Word 422
Variable Help:
Variable Handling: R
Variable Class: Dynamic | Correction
Variable Size: 2
Variable DataType: BitEnum
Variable Enum Value | Variable Enum Text |
---|---|
0x0001 | Temperature Out of Range |
0x0002 | Density Out of Range |
0x0004 | Line RTD Temperature Out of Range |
0x0008 | Meter RTD Temperature Out of Range |
0x0010 | Flow Direction |
0x0020 | Factory Configuration Data is Invalid |
0x0040 | Concentration Curve Fit Error |
0x0080 | Last Measured Value Override Active |
0x0100 | Concentration Extrapolation Error |
0x0200 | Calibration Factors Unentered |
0x0400 | Transmitter EEPROM Checksum Error |
0x0800 | Transmitter RAM Test Error |
0x1000 | Unrecognized/Unentered Sensor Type |
0x2000 | Core Configuration Database Corrupt |
0x4000 | Core Powerdown Totals Corrupt |
0x8000 | Core Program Corrupt |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
208 | 4127 | read_word_status |
Variable Write Command List
None