Loading…
Loading…
Variable Name: Word_421
Variable ID: 0x410C
Variable Label: Status Word 421
Variable Help: Reads Modbus register no. 421
Variable Handling: R
Variable Class: Dynamic | Correction
Variable Size: 2
Variable DataType: BitEnum
Variable Enum Value | Variable Enum Text |
---|---|
0x0001 | Burst Mode Enabled |
0x0002 | Power Reset Occurred |
0x0004 | Transmitter Initializing/Warming Up (Low Power Fault) |
0x0008 | Sensor/Xmtr Communication Failure (A28) |
0x0010 | Paper Out |
0x0020 | Event #2 Triggered |
0x0040 | Event #1 Triggered |
0x0080 | Sensor/Xmtr Communication Failure (A26) |
0x0100 | Calibration Failure (Autozero, Density, Temperature) |
0x0200 | Excess Calibration Correction, Autozero too Low |
0x0400 | Excess Calibration Correction, Autozero too High |
0x0800 | Process too Noisy to Perform Auto Zero |
0x1000 | Transmitter Failed |
0x2000 | Data Loss Possible (Totals+Inventories Questionable) |
0x4000 | Calibration-In-Progress (Autozero, Density, Temperature) |
0x8000 | Slug Flow |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
215 | 43E4 | read_additional_diags |
Variable Write Command List
None