Variable Name: status_info_bits
Variable ID: 0x404F
Variable Label: Informational
Variable Help: Informational messages indicate conditions that are not critical to measurement. Currently occuring conditions can be viewed from the Status menu; historical information can be viewed from the Diagnostic Info menu.
Variable Handling: R/W
Variable Class: Dynamic | Diagnostic | Device
Variable Size: 2
Variable DataType: BitEnum
Variable Enum Value | Variable Enum Text |
---|---|
0x0004 | Tank Dim Invld |
0x0400 | Signal Too Low |
0x0200 | Signal Too Hi |
0x0100 | DC Noise |
0x0080 | Uncertn Target |
0x0040 | Scatter Target |
0x0020 | Clutter Off Hi |
0x8000 | IPC Ack |
0x4000 | IPC Length |
0x2000 | IPC Checksum |
0x1000 | IPC Bus |
0x0002 | MultiEcho Dbl |
0x0001 | MultiEcho Trpl |
0x0800 | Info 0800 |
0x0010 | Info 0010 |
0x0008 | Info 0008 |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
149 | 40D2 | read_StatusInfoCodes |
Variable Write Command List
None