Variable Name: SZFault
Variable ID: 0x401F
Variable Label: SZ Fault State
Variable Help: Safety Zone Fault State defines how the Analog Output will respond when the transmitter detects a level that is within the Safety Zone which is a user defined area just below the Blocking Distance. Enable fault if necessary to ensure safe, reliable high-level readings in critical applications. If Latch3.6 or Latch22 is chosen, the unit will remain in alarm until it is manually cleared with the SZ Alarm Reset.
Variable Handling: R/W
Variable Class: Diagnostic | AnalogOut
Variable Size: 1
Variable DataType: Enum
Variable Enum Value | Variable Enum Text |
---|---|
0x0000 | None |
0x0001 | 3.6mA |
0x0002 | 22mA |
0x0003 | Latch3.6 |
0x0004 | Latch 22 |
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: N/A
Variable Min: N/A
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
175 | 40EC | read_SZfault |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
176 | 40ED | set_SZfault |