Variable Name: SZFault

Variable ID: 0x401F

Variable Label: SZ Fault State

Variable Help: Safety Zone Fault State defines how the Analog Output will respond when the transmitter detects a level that is within the Safety Zone which is a user defined area just below the Blocking Distance. Enable fault if necessary to ensure safe, reliable high-level readings in critical applications. If Latch3.6 or Latch22 is chosen, the unit will remain in alarm until it is manually cleared with the SZ Alarm Reset.

Variable Handling: R/W

Variable Class: Diagnostic | AnalogOut

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 None
0x0001 3.6mA
0x0002 22mA
0x0003 Latch3.6
0x0004 Latch 22

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
175 40EC read_SZfault

Variable Write Command List

Command Number Command ID Command Name
176 40ED set_SZfault