Loading…

Variable Name: PeakDetectThreshold

Variable ID: 0x4045

Variable Label: Peak Detect Thresh

Variable Help: Factory parameter, displayed for diagnostic purposes only.

Variable Handling: R/W

Variable Class: Device

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 20 mV
0x0001 50 mV
0x0002 110 mV
0x0003 160 mV
0x0004 250 mV
0x0005 440 mV

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
231 4121 read_PeakDetectThreshold

Variable Write Command List

Command Number Command ID Command Name
232 4122 set_PeakDetectThreshold