Loading…

Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field device status: Data indicating that the field device has detected condition(s) in the field device relating to: its hardware, the validity of a variable, its operating status or an internal process.

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 PV Analog Channel Saturated
0x0008 PV Analog Channel Fixed
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
132 4095 rcmB3Configuration
134 409B rcmLFCControlAndValues
140 40A3 rcmPulseOutputParameters
144 40B0 rcmLinearizationControl
148 40B2 rcmReadFirmwareVersion
149 40B4 rcmProductionOrderNumber
151 40C2 rcmDataOfOperatingFluid
153 40DC rcmLimitSwitchValuesAndControlforPV
156 40DF rcmNameOfOperatingFluid
163 40E6 rcmTypeOfDevice
170 40F0 rcmAdditionalInformationForLevel
172 40F2 rcmCompleteMeterSerialNumber
175 40F4 rcmLimitSwitchValuesAndControlforSV
176 40F6 rcmElectronicRevisionNumber
179 40F8 rcmIOModule
183 40FD rcmDisplayOrientationControlValue
184 40FE rcmLimitSwitchControl
207 4102 rcmReadArticleCodeIndices
244 4107 rcmReadDisplayAndAlarmConfiguration
247 4108 rcmReadDeviceVariableSpecificInformation
523 1303 read_condensed_status_map
246 411E rcmBe32EventsDeviceSpecificStatus
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables
50 1052 read_device_variable_assignments
54 1057 read_device_variable_information

Variable Write Command List

None