Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 Analog output 1 and its digital representation are outside the operating range limits, and not responding to input
0x0008 Analog output 1 and its digital representation are in fixed mode, and not responsive to input changes
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
134 40DC read_transmitter_specifics
138 40DD read_pv_sensor_range
139 40DE read_key_number
139 40DE read_key_number
139 40DE read_key_number
139 40DE read_key_number
140 40DF read_tableII
141 40E0 read_tableIII
142 40E1 read_time_in_svc
144 40E2 read_last_calib_time_date
148 40E3 read_power_fail_time_date
149 40E4 read_ET_upper_value
150 40E5 read_ET_lower_value
151 40E6 read_pv_uptrk
152 40E7 read_MBT_upper_value
153 40E8 read_MBT_lower_value
154 40E9 read_SP_value
155 40EA read_op_voltage
157 40EC read_M360_coreT_upTrk
158 40ED read_M360_coreT_dnTrk
159 40EE read_AVDD_max
160 40EF read_AVDD_min
161 40F0 read_install_date
162 40F1 read_MB_stress_monitor
164 40F3 read_table_IV
165 40F4 read_prev_calib_time_date
166 40F5 read_curr_calib_time_date
167 40F6 read_reset_correct_time_date
168 40F7 read_pv_dntrk
177 40FA read_database_ID
178 40FB read_config_history
178 40FB read_config_history
178 40FB read_config_history
178 40FB read_config_history
178 40FB read_config_history
178 40FB read_config_history
178 40FB read_config_history
178 40FB read_config_history
178 40FB read_config_history
178 40FB read_config_history
178 40FB read_config_history
145 40FC read_filter_sel
185 40FE read_lowflow_cutoff_mode
226 4100 read_lowflow_cutoff_brkpt
223 4102 read_sqrt_flow_val
186 4103 read_sensor_time_in_svc
187 4104 read_dev_fw_ver
220 4105 read_detailed_status
206 410A read_disp_view_info_I
206 410A read_disp_view_info_I
207 410B read_disp_view_info_II
207 410B read_disp_view_info_II
208 410C read_disp_view_info_III
208 410C read_disp_view_info_III
209 410D read_disp_view_info_IV
209 410D read_disp_view_info_IV
211 410F read_general_disp_conf
212 4110 read_disp_fw_ver
222 4112 read_sens_fw_ver
228 4113 read_avlble_for_maint_flag
230 4114 read_tamper_parameters
245 4117 read_Namur_level
64768 421F read_simple_disp_general_conf
64770 4221 read_simple_disp_flow_conf
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables
76 1045 read_lock_device_state

Variable Write Command List