变量名称: TIC_Value_2
变量ID: 0x41FF
变量标签: Totalizer value 2
变量描述: Displays the current totalizer counter. Additional information: Since the operating tool cannot display figures with more than 7 digits, the current counter above this range equals the sum of the totalizer counter plus the overflow displayed for the "Totalizer overflow @1" parameter. Example for how to calculate the current totalizer counter when the value exceeds the 7 digit display range limit of the operating tool: - Value of "Totalizer value @1" parameter: 1,968,457 m³ - Value of "Totalizer overflow @1" parameter: 1 × 107 m³ = 10,000,000 m³ - Current totalizer reading: 11,968,457 m³ In the event of an error, the totalizer behaves as specified in the "Failure mode" parameter.
变量处理: 读
变量分类: 动态
变量长度: 4
变量数据类型: 浮点
变量显示格式: |en|.5f
变量编辑格式:
变量单位:
变量最大值:
变量最小值:
变量读取命令列表
命令号 | 命令ID | 命令名称 |
---|---|---|
194 | 42E9 | read_index_parameter_194 |
变量写入命令列表
命令号 | 命令ID | 命令名称 |
---|---|---|
195 | 42E7 | write_index_parameter_195 |